CyberPower
CyberPower PR2000RT2UCN UPS 2000VA 2000W 120V 2U 8 Outlets
2U rack-tower UPS delivers 2000 VA and 2000 W sine-wave output through eight NEMA 5-20R outlets with 4.5 minutes runtime at full load
- International Version120V
- Input Voltage Range75 - 149 VAC
- Input Frequency47 - 63 Hz
- Input ConnectionNEMA 5-20P
- VA Rating2000 VA
- Watts2000 W
- Sine-wave output protects sensitive equipment with 2000 W pure sine wave delivery
- 2U rack/tower form factor fits standard racks or tower placement for flexible deployment
- Eight NEMA 5-20R outlets provide battery-backed power for multiple critical devices
- LCD status panel shows real-time voltage, load and battery information at a glance
- Three-hour recharge restores battery to 90 % capacity for rapid recovery after outages
2000 VA Sine-Wave UPS for Rack
The CyberPower PR2000RT2UCN delivers 2000 VA and 2000 W of pure sine-wave output in a 2U form factor that mounts in a rack or stands as a tower. Eight NEMA 5-20R outlets provide battery-backed surge protection for servers, networking gear and storage arrays. A NEMA 5-20P input plug with a 10 ft cord connects to 120 VAC mains. Line-interactive topology corrects voltage without battery drain.
Line-Interactive Design
The unit accepts an input range of 75 to 149 VAC at 47 to 63 Hz and regulates output to 100, 110, 120 or 125 VAC within five percent. Because the topology is line interactive, the inverter engages only during outages or severe distortion, keeping audible noise low and reducing battery cycles. Sealed lead-acid batteries recharge from zero to ninety percent in three hours. Replaceable battery modules extend service life without replacing the whole chassis.
PowerPanel Business Software
Bundled PowerPanel Business software connects through a serial port to give graceful shutdown, scheduling and event logging across multiple systems. A dry-contact port adds a second path for building-management or SNMP cards to signal battery mode, low battery, overload, overcharge or overheat alarms. Together these interfaces let administrators automate responses without proprietary hardware.
Βασικά χαρακτηριστικά
- Sine-wave output protects sensitive equipment with 2000 W pure sine wave delivery
- 2U rack/tower form factor fits standard racks or tower placement for flexible deployment
- Eight NEMA 5-20R outlets provide battery-backed power for multiple critical devices
- LCD status panel shows real-time voltage, load and battery information at a glance
- Three-hour recharge restores battery to 90 % capacity for rapid recovery after outages
Προδιαγραφές
| Brand | CyberPower |
|---|---|
| Series | Smart App Sinewave UPS Series |
| Model | PR2000RT2UCN |
| International Version | 120V |
| Input Voltage Range | 75 - 149 VAC |
| Input Frequency | 47 - 63 Hz |
| Input Connection | NEMA 5-20P |
| VA Rating | 2000 VA |
| Watts | 2000 W |
| Output Voltage | 100/110/120/125 VAC +/- 5% |
| Output Frequency | 50/60 Hz +/- 1% |
| Outlets | 8 |
| Outlet Type | 8 x NEMA 5-20R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Full Load 4.5 min Half Load 13.5 min |
| Battery Recharge Time | 3 Hours (0% to 90% charged) |
| Battery Replaceable | Yes |
| Alarms | Battery Mode Low Battery Overload Overcharge Overheat |
| Interface Port | 1 Serial, 1 Dry Contact |
| Management Software | PowerPanel Business |
| Surge Energy Rating | 2430 Joules |
| Protection | On Battery: Internal Circuitry Limiting On Utility: Circuit Breaker Protected |
| Dimensions | 17.1" x 3.4" x 16.2" |
| Weight | 59.8 lbs. |
| Βάρος αποστολής | 30.84 kg |
| Διαστάσεις συσκευασίας | 561 × 531 × 274 mm |
Ερωτήσεις για αυτό το προϊόν
How do I install the PR2000RT2UCN in a 2U rack and what step is commonly missed?
Mount the 2U chassis using the included brackets, plug the NEMA 5-20P cord into a 20 A branch circuit, then connect the serial or dry-contact cable to your server so PowerPanel Business can trigger graceful shutdowns — the management link is the step most often skipped.
What battery maintenance will the unit need and when?
The sealed lead-acid batteries are user-replaceable; expect to swap them every three to five years, and after a deep discharge allow the three-hour recharge to 90 % before returning to full runtime.
What runtime limit appears first during a prolonged outage at full load?
At 2000 W the battery lasts 4.5 minutes, so the low-battery alarm and automatic shutdown occur long before any thermal or overload limit is reached.