APC
APC SRT6KXLT-5KTF UPS 6000VA 208/240V-120V 17 Outlets
Provides 6000 VA battery backup with 208/240V to 120V step-down and 17 outlets
- International Version208V
- Input Frequency40 - 70 Hz (auto sensing)
- Input ConnectionHard Wire 3-wire (2PH + G)
- VA Rating6000 VA
- Watts6000 Watts
- Output Voltage120V, 208V
- 6000 VA and 6000 W deliver full power to critical loads
- 17 outlets including NEMA L14-30R, L6-30R, L6-20R and 5-20R support diverse equipment
- Built-in 208/240V to 120V step-down transformer enables flexible voltage distribution
- 50 hour battery recharge time restores backup readiness quickly
- RJ-45, USB, Smart-Slot and serial interfaces provide comprehensive network management
6000 VA Step-Down UPS for Mixed Voltage Racks
The APC Smart-UPS SRT 6000 VA unit delivers 6000 watts of double-conversion backup power while converting a 208/240 V input to 120 V and 208 V outputs. Seventeen outlets include hard-wire, NEMA L14-30R, three NEMA L6-30R, four NEMA L6-20R and eight NEMA 5-20R connections. Network management is provided through RJ-45 10/100 Base-T, serial, Smart-Slot and USB interfaces.
Suited for Data Centres Needing 120 V
IT managers running servers, storage arrays and network gear that require both 120 V and 208 V circuits can power all loads from a single 208/240 V hard-wire input. Sites without three-wire 2PH plus ground supply, or that need only 120 V or only 208 V output, should consider a simpler UPS without the step-down transformer.
1.5 Hour Battery Recharge Determines Recovery Window
After a full discharge the internal battery pack reaches full charge in 1.50 hours, so the length of any subsequent outage must fit within that recharge cycle or additional battery modules must be added.
Põhijooned
- 6000 VA and 6000 W deliver full power to critical loads
- 17 outlets including NEMA L14-30R, L6-30R, L6-20R and 5-20R support diverse equipment
- Built-in 208/240V to 120V step-down transformer enables flexible voltage distribution
- 50 hour battery recharge time restores backup readiness quickly
- RJ-45, USB, Smart-Slot and serial interfaces provide comprehensive network management
Tehnilised andmed
| Brand | APC |
|---|---|
| Model | SRT6KXLT-5KTF |
| International Version | 208V |
| Input Frequency | 40 - 70 Hz (auto sensing) |
| Input Connection | Hard Wire 3-wire (2PH + G) |
| VA Rating | 6000 VA |
| Watts | 6000 Watts |
| Output Voltage | 120V, 208V |
| Output Frequency | 50/60Hz +/- 3 Hz |
| Outlets | 17 |
| Outlet Type | 1 x Hard Wire 3-wire (2PH + G) (Battery Backup) 1 x NEMA L14-30R (Battery Backup) 3 x NEMA L6-30R (Battery Backup) 4 x NEMA L6-20R (Battery Backup) 8 x NEMA 5-20R (Battery Backup) |
| Battery Recharge Time | 1.50 Hour(s) |
| Battery Replaceable | APCRBC140 |
| Alarms | Audible and visible alarms prioritized by severity |
| Interface Port | RJ-45 10/100 Base-T , RJ-45 Serial , Smart-Slot , USB |
| Surge Energy Rating | 480 Joules |
| Features | APC Smart-UPS SRT 6000 VA with 208 / 240V to 120V Step-Down Transformer |
| Dimensions | 17.00" x 11.95" x 28.32" |
| Weight | 260.00 lbs. |
| Tarnekaal | 127.91 kg |
| Pakendi mõõtmed | 980 × 718 × 610 mm |
Küsimused selle toote kohta
What hard-wire input connection does the UPS require?
The unit needs a hard-wire 3-wire (2PH + G) feed on a 208 V circuit rated for the 6000 VA load.
Can I keep using my existing NEMA L6-30R and NEMA 5-20R power cords with the 17 outlets provided?
Yes, the UPS supplies 3 x NEMA L6-30R, 4 x NEMA L6-20R, 1 x NEMA L14-30R and 8 x NEMA 5-20R battery-backup outlets.
How do I confirm the UPS is operating normally after installation?
Check the front-panel LCD for a green status icon, verify output reads 120 V or 208 V at 50/60 Hz ±3 Hz, and ensure no audible or visible alarms are active.
Veel samast osakonnast
Kliendid võrdlesid neid ka
Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.
Black Box Corporation DisplayPort to DVI Fibre Optic Cable 15 ft 4.5 m 1.35 GB/s
- Consumer Electronics