Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.

Hinnavaatlus Logi sisse

HPE

HPE MSA 2070 SFF 2x10/25GbE iSCSI 4-port Cntrl 12x3.84TB SSD 4x10Gb iSCSI XCVR 46TB Storage Array (P76569-B25)

SKU CH-14AJ-8TB44 MPN P76569-B25

A 2U SFF storage array with 12 installed 3.84 TB SAS SSDs, dual 10/25 GbE iSCSI controllers, four 10 Gb transceivers and redundant 580 W power supplies

  • WorkloadStorage Server
  • TypeSmall Form Factor
  • Rack Height2U
  • Storage ControllerTwo 10/25 GbE iSCSI 4-port controllers
  • SSD (Installed)12 x 3.84TB SAS SSD
  • Max HDD CapacityUp to 2.73 PB with maximum capacity expansion

SSD (Installed) 12 x 3.84TB SAS SSD

Option 4 x 10 Gb iSCSI SFP+ transceivers

  • Twelve 3.84 TB SAS SSDs deliver 46.08 TB of flash capacity
  • Dual 10/25 GbE iSCSI 4-port controllers provide redundant host connectivity
  • Four 10 Gb iSCSI SFP+ transceivers included for immediate network integration
  • Two 580 W redundant power supplies maintain uptime during single-supply failure
  • 2U SFF chassis supports up to 24 drives with expansion enclosures to 2.73 PB

HPE MSA 2070 46TB All-Flash Array

The HPE MSA 2070 Gen7 is a 2U SFF storage server pre-populated with twelve 3.84TB SAS SSDs for 46.08TB raw capacity. Dual 10/25GbE iSCSI 4-port controllers deliver high-throughput block access for virtualised workloads. It targets SMBs and remote offices needing affordable shared storage that scales beyond the base enclosure.

Build Integration: Controllers, Power and Expansion

Two 12Gb/s SAS controllers manage the installed drives and connect to optional 2U 24-drive SFF or 12-drive LFF expansion enclosures, supporting up to 2.73PB total. Two redundant 580W power supplies maintain uptime during module failure. Four 10Gb iSCSI SFP+ transceivers ship in the box for immediate network connectivity. Certified for Windows Server, VMware vSphere, Red Hat Linux and SUSE SLES.

Sustained Operation: Firmware Updates

Gen7 architecture enables online system and media firmware updates without service interruption, reducing maintenance windows. The integrated HPE MSA Health Check tool simplifies routine diagnostics and capacity planning. Designed for continuous read-intensive workloads across mixed virtual machine and database tiers.

Põhijooned

  • Twelve 3.84 TB SAS SSDs deliver 46.08 TB of flash capacity
  • Dual 10/25 GbE iSCSI 4-port controllers provide redundant host connectivity
  • Four 10 Gb iSCSI SFP+ transceivers included for immediate network integration
  • Two 580 W redundant power supplies maintain uptime during single-supply failure
  • 2U SFF chassis supports up to 24 drives with expansion enclosures to 2.73 PB

Tehnilised andmed

BrandHPE
SeriesMSA 2070 Gen7
ModelP76569-B25
WorkloadStorage Server
TypeSmall Form Factor
Rack Height2U
Storage ControllerTwo 10/25 GbE iSCSI 4-port controllers
SSD (Installed)12 x 3.84TB SAS SSD
Max HDD CapacityUp to 2.73 PB with maximum capacity expansion
Compatible/Certified OSWindows Server
VMware vSphere
Red Hat Linux
SUSE SLES
Power CharacteristicsTwo 580W redundant power supplies
Package ContentsFour 10 Gb iSCSI SFP+ transceivers
Tarnekaal13.61 kg
Pakendi mõõtmed762 × 635 × 254 mm

Selle mudeli teised versioonid

5 veel samast sarjast

Sama seeria, erinev mälumaht, jahutus või taktsagedus — võrrelge enne otsustamist.

Küsimused selle toote kohta

How many drive bays remain free after the twelve 3.84TB SSDs are installed?

The 2U chassis has 24 SFF bays total, so twelve bays are still available for additional SAS SSDs or HDDs.

What is the heat load from the redundant power supplies when the array runs continuously?

Two 580W redundant supplies are fitted; actual draw depends on the final drive count and workload.

Which host-side network ports must the customer already have to use the four included 10Gb iSCSI transceivers?

The transceivers are SFP+ modules, so the connecting switches or servers need compatible 10GbE SFP+ ports.

Veel samast osakonnast

Kliendid võrdlesid neid ka