NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.
myVolts
Enclosed 75 W switching supply delivering 15 V at 5 A with universal 85-264 VAC input, 300 VAC surge tolerance, sub-0.3 W no-load draw and 70 °C operating limit
The myVolts LRS-75-15 is a single-output enclosed switching power supply delivering 15 V at 5 A for 75 W total. It suits industrial automation, control cabinets, 3D printers and household appliances that require a compact 1U low-profile unit. Universal AC input from 85 to 264 VAC allows worldwide operation without manual switching. The unit carries safety approvals including TUV EN62368-1, UL62368-1 and GB4943 for regulated environments.
Cooling relies on free air convection, so the supply runs silently with no fan noise in normal use. It operates up to 70 °C and at altitudes up to 5000 metres while maintaining full load capability. No-load power consumption stays below .3 W, and the design withstands 300 VAC surge input for 5 seconds. Built-in protections cover short circuit, overload and over voltage, and a 5 G vibration rating adds mechanical ruggedness.
A green LED signals power-on status for quick visual verification in a cabinet. The supply complies with IEC/EN60335-1 PD3 and IEC/EN61558-1, -2-16 for household appliance safety, and meets over voltage category III requirements. Every unit undergoes 100 % full-load burn-in test before shipment, and the manufacturer backs the series with a three-year warranty. No additional cables or software are bundled.
| Type | AT |
|---|
Mount the enclosed supply on a flat metal surface using the chassis screw holes; keep ventilation gaps above and below so free-air convection can dissipate heat up to the 70 °C operating limit.
No moving parts to service; periodically vacuum dust from the vent slots and verify the power-on LED stays lit to confirm the supply remains healthy.
The unit delivers full 75 W up to 70 °C ambient; above that temperature the output must be reduced to stay within thermal limits.
Veel samast osakonnast
Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.
See, millega maksate, ja see, milles vaatate hindu.
Saadetud teie rahakotist kassas
Ainult kuvamiseks — kataloogi hinnad on dollarites
Ükski vääring ei vasta sellele.
Valige keel, milles sait teiega räägib.
Esimest korda siin?
Teil on juba konto?
Automaatset lähtestamist ei ole: see pood ei saada ühtegi e-kirja, seega pole ka ühekordset linki, mida küsida. Jätke aadress kontole alles, seda käsitletakse käsitsi.
Päring registreeritud
Teie postkasti ei jõua midagi — see pood ei saada e-kirju üldse. Keegi tegeleb sellega käsitsi.
Tuli meelde?