NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.
myVolts
A 12V 40A 480W switch-mode power supply with overload, overvoltage and short-circuit protection for industrial automation, LED displays, CCTV and 3D printers
The myVolts S-480-12 delivers a regulated DC 12V output at up to 40A for 480W continuous power. It accepts AC110/220V input with a ±15% tolerance, making it suitable for industrial automation, LED displays, CCTV systems, 3D printers and similar fixed installations.
Builders replacing 36W or 50W AT-type supplies gain the headroom needed for larger LED arrays or multi-device rails without adding extra modules. The jump is worth it when a single 12V rail must feed several loads simultaneously and the previous unit hits its current limit or thermal shutdown.
The AT layout uses screw terminals for L, N, GND, V and ADJ connections rather than standard ATX connectors, so it cannot power a PC motherboard directly. Operating temperature is rated 0–40°C with 0–95% non-condensing humidity, and the unit relies on natural convection cooling, which restricts use in sealed or high-ambient enclosures.
| Type | AT |
|---|
The unit measures approximately 85 x 58 x 33 mm, so allow that footprint plus clearance for the aluminium-alloy case and screw terminals.
Connect live and neutral to L and N for 110/220 V AC, then attach the load to V+ and GND; the frequent error is leaving the ADJ potentiometer at factory setting instead of trimming it to exactly 12 V before powering the load.
Operate between 0 and 40 °C with humidity below 95 % non-condensing; periodically blow dust from the natural-convection vents and re-check the output voltage with a multimeter after the first 100 % load burn-in period.
Veel samast osakonnast
Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.
See, millega maksate, ja see, milles vaatate hindu.
Saadetud teie rahakotist kassas
Ainult kuvamiseks — kataloogi hinnad on dollarites
Ükski vääring ei vasta sellele.
Valige keel, milles sait teiega räägib.
Esimest korda siin?
Teil on juba konto?
Automaatset lähtestamist ei ole: see pood ei saada ühtegi e-kirja, seega pole ka ühekordset linki, mida küsida. Jätke aadress kontole alles, seda käsitletakse käsitsi.
Päring registreeritud
Teie postkasti ei jõua midagi — see pood ei saada e-kirju üldse. Keegi tegeleb sellega käsitsi.
Tuli meelde?