Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.
Seagate
20 TB SATA 6.0 Gb/s 7200 RPM 3.5" host-managed SMR drive with 256 MB cache for sequential write-intensive workloads
The Seagate Exos X20z ST20000NM001J is a 20 TB 3.5-inch internal hard drive spinning at 7200 RPM on a SATA 6.0 Gb/s interface. It uses host-managed shingled magnetic recording with a 256 MB cache and is built for continuous 24/7 operation in enterprise environments.
This drive fits data centres and bulk-storage arrays that can manage SMR zones directly in software. It is not for general desktop use, boot drives or random-access databases that need conventional magnetic recording. Builders without host-aware file systems or object-store layers should look elsewhere.
The drive mounts in any 3.5-inch bay with standard SATA data and power cables. No special drivers are required, but the host must implement zone management for the SMR layout; treating it as a regular block device will cause severe write stalls and premature wear. Zone-aware software is the only common pitfall.
| Brand | Seagate |
|---|---|
| Series | Exos X20z |
| Model | ST20000NM001J |
| Part Number | 2U6101-114 |
| Capacity | 20TB |
| RPM | 7200 RPM |
| Interface | SATA 6.0Gb/s |
| Cache | 256MB |
| Recording Technology | SMR |
| Form Factor | 3.5" |
| Features | Host-Managed SMR |
The ST20000NM001J uses Host-Managed SMR technology, so the operating system or application must implement the ZBC/ZAC command set to control the sequential write zones.
Most hardware RAID controllers treat the drive as a normal block device and cannot issue the zone commands that Host-Managed SMR requires, so performance will degrade or the array may fail.
Use a zone-aware tool such as libzbc or smartctl to report the zone type and write-pointer position; sequential zones should show an advancing write pointer after each write.
Veel samast osakonnast
Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.
See, millega maksate, ja see, milles vaatate hindu.
Saadetud teie rahakotist kassas
Ainult kuvamiseks — kataloogi hinnad on dollarites
Ükski vääring ei vasta sellele.
Valige keel, milles sait teiega räägib.
Ükski keel ei vasta.
Esimest korda siin?
Teil on juba konto?
Automaatset lähtestamist ei ole: see pood ei saada ühtegi e-kirja, seega pole ka ühekordset linki, mida küsida. Jätke aadress kontole alles, seda käsitletakse käsitsi.
Päring registreeritud
Teie postkasti ei jõua midagi — see pood ei saada e-kirju üldse. Keegi tegeleb sellega käsitsi.
Tuli meelde?