Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.

Hinnavaatlus Logi sisse

Vertiv

Vertiv GXT5-3000LVRT2UXLN 3000VA 2700W 120V UPS 2U Rack/Tower

SKU CH-HZ0R-SCA7E MPN GXT5-3000LVRT2UXLN

Delivers 3000VA pure sine-wave backup with seven configurable outlets and an included network card in a 2U rack/tower form factor

  • International Version120V
  • Input Voltage Range60-150V
  • Input Frequency40-70Hz; Auto Sensing
  • Input ConnectionNEMA L5-30P
  • VA Rating3000VA
  • Watts2700W
  • Pure sine wave output protects sensitive equipment
  • 3000VA 2700W capacity handles demanding server loads
  • 2U rack/tower form factor fits standard racks or desks
  • Seven outlets include L5-30R and six 5-20R receptacles
  • RDU120 network card enables remote monitoring and management

Purpose-built UPS

The Vertiv GXT5-3000LVRT2UXLN is a 3000VA, 2700W online double-conversion UPS that delivers pure sine-wave output at 120V. It mounts in a 2U rack or stands as a tower and includes an RDU120 network card for remote monitoring. Seven outlets, one NEMA L5-30R and six NEMA 5-20R, support a range of IT loads.

Who it suits

This unit fits network closets, edge sites and small server rooms that need runtime measured in minutes rather than hours. Buyers who require extended battery autonomy at full load should look at larger-capacity UPS models or external battery cabinets. Sites without a NEMA L5-30P supply will need an alternative input connection.

Sustained-load behaviour

At half load the internal VRLA batteries provide 12.6 minutes of runtime; at full load the figure drops to 4 minutes. The UPS accepts a wide 60-150V input window and auto-senses 40-70Hz, so it stays online through prolonged voltage sags without draining the battery. Operating temperature range is 32°F to 104°F.

Põhijooned

  • Pure sine wave output protects sensitive equipment
  • 3000VA 2700W capacity handles demanding server loads
  • 2U rack/tower form factor fits standard racks or desks
  • Seven outlets include L5-30R and six 5-20R receptacles
  • RDU120 network card enables remote monitoring and management

Tehnilised andmed

BrandVertiv
SeriesLiebert
ModelGXT5-3000LVRT2UXLN
International Version120V
Input Voltage Range60-150V
Input Frequency40-70Hz; Auto Sensing
Input ConnectionNEMA L5-30P
VA Rating3000VA
Watts2700W
Output Voltage110/115/120/125VAC; (user-configurable); +/-3%
Outlets7
Outlet Type1 x NEMA L5-30R, 6 x NEMA 5-20R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeHalf Load: 12.6 min
Full Load: 4 min
ApprovalsUL 1778 4th Edition and CSA 22.2 No 107.3
TemperatureOperating Temperature: 32°F - 104°F (0°-40°)
Storage Temperature: -4°F - 140°F (-20°-60°)
Humidity0% to 95%, non-condensing
Dimensions3.4" x 16.9" x 18.5"
Weight47.5 lbs.
Package Contentswith RDU120 Network Card
Tarnekaal35.50 kg
Pakendi mõõtmed719 × 566 × 254 mm

Küsimused selle toote kohta

What input plug must my electrical circuit provide for the NEMA L5-30P connection on this UPS?

The UPS requires a NEMA L5-30P receptacle on a 120 V circuit capable of supplying up to 24 A.

Can I plug legacy 5-15P devices into the six NEMA 5-20R outlets without adapters?

Yes, the 5-20R outlets accept both 5-15P and 5-20P plugs, so older 15 A equipment connects directly.

How do I verify the RDU120 network card is communicating after installation?

Log into the card's web interface or SNMP manager; it will display real-time voltage, load percentage, battery status and alarm logs.