APC AP7801B Metered PDU 1U 20A 120V 8x5-20R
Metered 1U rack PDU delivers 120V power to eight NEMA 5-20R outlets with a local current display and remote monitoring to prevent overloads
- TypeMetered
- Rack Size1U
- StyleSchneider Electric Rack PDU, Metered, 1U, 20A, 120V, 8 5-20
- CertificationscUL Listed, CSA, FCC Part 15 Class A, ICES-003, UL 60950, UL
- ROHSYes
- Input Voltage100V, 120V
- Real-time load monitoring prevents overloads with local current display
- Remote management via StruxureWare integration enables centralised power oversight
- Eight NEMA 5-20R outlets distribute 120 V power to rack equipment
- 12-foot input cord with NEMA L5-20P plug reaches distant power sources
- cUL, CSA, FCC and UL 60950 certifications confirm safety compliance
Metered 1U PDU with 8 NEMA 5-20R outlets
The APC AP7801B is a metered rack power distribution unit that occupies one rack unit and delivers 120V power through eight NEMA 5-20R receptacles. It connects via a NEMA L5-20P plug on a 12-foot cord and supports input voltages of 100V or 120V at 50/60 Hz. The unit is cUL Listed, CSA certified and meets FCC Part 15 Class A requirements. It is built for IT environments that need local current visibility and remote load tracking.
Local display and remote monitoring under
A built-in LED load indicator and local current monitoring display show real-time draw so operators can watch sustained consumption without opening the rack. The PDU integrates with StruxureWare Data Center Expert for remote management and user-defined alarms that warn before a circuit reaches its regulatory derated limit of 16A. Firmware is flash upgradeable, allowing long-term feature updates without hardware replacement. These tools help prevent overloads during extended operation.
120V 20A branch circuit defines the practical
The output is rated at 120 volts x 20 amps, but the regulatory derated input current is 16A, so continuous loads must stay within that 16A boundary. The eight NEMA 5-20R outlets share this single branch, meaning total connected equipment cannot exceed the derated value without tripping the upstream breaker. Operating temperature range is -5 to 45 degrees Celsius, so airflow and ambient conditions must support that envelope. No higher voltage or alternative connector options are provided.
Erősségek
- Real-time load monitoring prevents overloads with local current display
- Remote management via StruxureWare integration enables centralised power oversight
- Eight NEMA 5-20R outlets distribute 120 V power to rack equipment
- 12-foot input cord with NEMA L5-20P plug reaches distant power sources
- cUL, CSA, FCC and UL 60950 certifications confirm safety compliance
Műszaki adatok
| Brand | APC |
|---|---|
| Series | Rack PDU |
| Model | AP7801B |
| Part Number | AP7801B |
| Type | Metered |
| Rack Size | 1U |
| Style | Schneider Electric Rack PDU, Metered, 1U, 20A, 120V, 8 5-20 |
| Certifications | cUL Listed, CSA, FCC Part 15 Class A, ICES-003, UL 60950, UL Listed |
| ROHS | Yes |
| Input Voltage | 100V, 120V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 16A |
| Regulatory Derated Input Current | 16A |
| Input Connector(s) | NEMA L5-20P |
| Cord Length | 12 Feet |
| Output Voltage | 120V |
| Output Frequency | 50/60 Hz |
| Output Watts (VA) | 120 volts x 20 amps |
| Output Connector(s) | 8 x NEMA 5-20R (Battery Backup) |
| Operating Environment | -5 - 45 Degree Celcius |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 Degree Celcius |
| Storage Relative Humidity | 5 - 95% |
| Storage Elevation | 0 - 15000 m |
| Features | Local and web-based monitoring Local Current Monitoring Display Load indicator LED Alarm Thresholds Wide range of input and output connections |
| Dimensions | 1.74" x 17.47" x 4.03" |
| Weight | 3.80 lbs. |
| Szállítási súly | 3.61 kg |
| Csomagméret | 489 × 343 × 70 mm |
Kérdések a termékről
How much power does the AP7801B draw when the 20 A circuit is fully loaded all day?
The unit passes up to 16 A continuously through its NEMA L5-20P plug, so heat and fan noise scale with the connected load rather than a fixed overhead.
Which inlet cable and branch-circuit breaker must already be in place for the AP7801B to operate?
A NEMA L5-20P inlet on a 12 ft cord requires a matching 20 A locking receptacle and a 20 A branch circuit rated for 120 V service.
Will the AP7801B metering and remote features work with legacy servers that only have basic IEC power cords?
Yes — the eight NEMA 5-20R outlets accept standard 5-15 or 5-20 plugs, and the local LED display plus StruxureWare integration function independently of the attached equipment age.
Szintén ezen a polcon
Vásárlók ezeket hasonlították össze
Ugyanaz a polc, ugyanaz a pénztár — nyolc pénznem és 30 perces árfolyamzár.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case