MINUTEMAN ED2000RTXL2UNC 2000VA 1800W 2U UPS
2U double-conversion UPS delivers 2000VA/1800W with 120V output, eight 5-15/20R plus one L5-20R receptacles, and 12-minute half-load runtime
- International Version120V
- Input Voltage Range0-160VAC
- Input Frequency50/60Hz +/- 6Hz Auto-sensing
- Input ConnectionNEMA 5-20P
- VA Rating2000VA
- Watts1800W
Model ED2000RTXL2UNC
- ED2000RTXL2UNC
- ED1000RTXL2U
- ED1000RTXL2UNC
- ED10KRT
- ED10KRT-10KTF2
- ED10KRT-3KTF
- ED10KRT-5KTF
- ED10KRT-6KTF2
- ED10KRT-8KTF2
- ED10KTF
- ED2000RTXL2U
- ED3000RTXL2U
Még 16 konfiguráció megtekintése
- ED3000RTXL2UNC
- ED-3KTF
- ED5KRT
- ED5KRT-3KTF
- ED5KRT-5KTF
- ED-5KTF
- ED6KRT
- ED6KRT-3KTF
- ED6KRT-5KTF
- ED6KRT-6KTF2
- ED6KTF
- ED8KRT
- ED8KRT-3KTF
- ED8KRT-5KTF
- ED8KRT-6KTF2
- ED8KRT-8KTF2
Az áthúzott konfigurációk léteznek, de nem érhetők el itt.
- True on-line double conversion protects critical loads
- 2U rack height fits dense server cabinets
- 9 output power factor delivers 1800 W from 2000 VA
- LCD display shows status at a glance
- Three controllable load banks extend runtime for priority gear
2U On-Line UPS for Dense Racks
The Minuteman Endeavor ED2000RTXL2UNC is a 2000VA 1800W double-conversion unit in a 2U chassis. It suits server rooms and network closets where clean 120V output and flexible mounting matter. True on-line topology isolates connected gear from every input anomaly. The 0.9 output power factor supports modern power supplies efficiently.
Replaces Line-Interactive Units When Uptime Is
Step up from line-interactive models when equipment cannot tolerate any transfer time or voltage distortion. The jump is worth it for loads that demand continuous sine-wave output through brownouts, sags and frequency drift. Input range of 0-160VAC handles severe utility swings without draining the battery. Selectable 110VAC output accommodates legacy hardware.
Four Minutes at Full Load Then Eight-Hour Recharge
At 1800W the sealed lead-acid pack delivers four minutes of run time; half load extends this to twelve minutes. Recharge to 90 percent takes eight hours from total discharge. Economy mode reduces losses during stable utility conditions. Three controllable load banks let administrators shed non-critical outlets to extend backup for essential devices.
Erősségek
- True on-line double conversion protects critical loads
- 2U rack height fits dense server cabinets
- 9 output power factor delivers 1800 W from 2000 VA
- LCD display shows status at a glance
- Three controllable load banks extend runtime for priority gear
Műszaki adatok
| Brand | MINUTEMAN |
|---|---|
| Series | ENDEAVOR |
| Model | ED2000RTXL2UNC |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/- 6Hz Auto-sensing |
| Input Connection | NEMA 5-20P |
| VA Rating | 2000VA |
| Watts | 1800W |
| Output Voltage | 120VAC, User selectable: 110VAC |
| Output Frequency | 50/60Hz +/- 0.5Hz unless synchronized to line |
| Outlets | 9 |
| Outlet Type | 8 (5-15/20R) & 1 (L5-20R) |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 12 min Full Load: 4 min |
| Battery Recharge Time | 8 hours to 90% from total discharge |
| Battery Replaceable | BM0037 |
| Approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU) |
| Surge Energy Rating | 1000 Joules |
| Temperature | Operating Temperature: +32 to +104°F (0 to 40°C) Storage Temperature: +5 to +113°F (-15 to +45°C) |
| Humidity | 95% non-condensing |
| Dimensions | 3.5" x 19" x 17" |
| Weight | 47.6 lbs. |
| Szállítási súly | 25.86 kg |
| Csomagméret | 597 × 549 × 224 mm |
A modell további verziói
5 további ebben a termékcsaládban
Ugyanaz a termékcsalád, eltérő memória, hűtés vagy órajel — hasonlítsa össze, mielőtt dönt.
MINUTEMAN ED2000RTXL2U 2000VA 1800W 120V 2U UPS
- 120V
- 0-160VAC
MINUTEMAN ED3000RTXL2U 3000VA 2700W UPS 2U Tower/Rack/Wall Mountable
- 120V
- 0-160VAC
Kérdések a termékről
What rack space and wall-mount kit does the 2U UPS need?
The unit occupies 2U of rack height, measures 19 inches wide and 3.5 inches high, and rackmount ears come attached; an optional install kit is required for wall mounting.
Which input plug and circuit are required for the 2000VA model?
Connect the NEMA 5-20P input to a 120 V AC, 20 A branch circuit; the UPS auto-senses 50/60 Hz input frequency.
When and how do I replace the internal battery?
Replace the sealed lead-acid battery (part BM0037) when runtime drops below the 12-minute half-load or 4-minute full-load figures; allow 8 hours to reach 90 % charge after installation.
Szintén ezen a polcon
Vásárlók ezeket hasonlították össze
Ugyanaz a polc, ugyanaz a pénztár — nyolc pénznem és 30 perces árfolyamzár.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case