Eaton
Eaton SU6000RTFMB 6000VA UPS 230V In Multi-Out
A 6000 VA rack or tower UPS with hot-swappable lead-acid batteries, automatic voltage regulation, a maintenance bypass, and network management card included
- Input Voltage Range230 V AC
- Output Voltage100 V AC 110 V AC 230 V AC 200 V AC 208 V AC 220 V AC 240 V
- Output Frequency50 Hz 60 Hz
- AlarmsLow Battery Utility Power Failure Remote Shutdown
- FeaturesGreen Energy Saving Cold Start Function Audible Alarm
- Package ContentsSmartOnline SU6000RTFMB 6000VA Rack/tower UPS SUTFMR 120V St
- 6000VA capacity protects critical loads during outages
- 3 minutes full-load runtime sustains equipment through short power cuts
- 8 minutes half-load runtime extends uptime for lighter workloads
- Hot-swappable lead-acid batteries enable replacement without downtime
- Multi-voltage output supports 100V to 240V equipment worldwide
6000VA rack/tower UPS with transformer and bypass
This 6000VA online UPS delivers continuous 230V power from a 180V DC battery system. It includes a 120V step-down transformer and a maintenance bypass module so servicing can occur without interrupting connected equipment. The unit operates in either rack or tower orientation and ships with a network management card for remote monitoring.
Suited for multi-voltage loads needing zero
The wide output range covers 100V, 110V, 120V, 200V, 208V, 220V, 230V and 240V at both 50Hz and 60Hz, making it useful for mixed-voltage server rooms or lab gear. Buyers who only require short runtime for a single-voltage rack should look at smaller units without the integrated transformer and bypass.
Runtime at full load is three minutes
At 100 per cent load the battery provides three minutes of backup; at half load it extends to eight minutes. Cold-start capability lets the UPS power on without utility present, and hot-swappable lead-acid modules can be replaced while the system stays online.
Privalumai
- 6000VA capacity protects critical loads during outages
- 3 minutes full-load runtime sustains equipment through short power cuts
- 8 minutes half-load runtime extends uptime for lighter workloads
- Hot-swappable lead-acid batteries enable replacement without downtime
- Multi-voltage output supports 100V to 240V equipment worldwide
Specifikacijos
| Brand | EATON |
|---|---|
| Part Number | SU6000RTFMB |
| Input Voltage Range | 230 V AC |
| Output Voltage | 100 V AC 110 V AC 230 V AC 200 V AC 208 V AC 220 V AC 240 V AC 120 V AC |
| Output Frequency | 50 Hz 60 Hz |
| Alarms | Low Battery Utility Power Failure Remote Shutdown |
| Features | Green Energy Saving Cold Start Function Audible Alarm |
| Package Contents | SmartOnline SU6000RTFMB 6000VA Rack/tower UPS SUTFMR 120V Stepdown Transformer SUPDMBP6K Maintenance Bypass WEBCARDLXE Network Card USB Cable RS-232 Cable Tower Support Stands Cable Gland for Hardwire Connection Rack-mounting Hardware for UPS and Transformer Maintenance Bypass Mounting Hardware DB9 Serial Cables Quick Start Guide |
| Siuntos svoris | 93.67 kg |
| Pakuotės dydis | 864 × 439 × 259 mm |
Klausimai apie šią prekę
How long does the battery last at full load before shutdown?
The unit provides three minutes of backup at full load and eight minutes at half load.
Does the fan noise or heat output change during continuous operation?
The specifications list an audible alarm but do not detail fan noise or thermal behaviour under sustained use.
What external equipment is required before the UPS can power connected devices?
A 230 V AC supply, the included step-down transformer, maintenance bypass module, network card and all supplied cables and mounting hardware must be installed.
Taip pat šiame skyriuje
Kiti pirkėjai taip pat lygino
Ta pati lentyna, tas pats atsiskaitymas — aštuonios monetos ir 30 minučių fiksuotas kursas.
Black Box Corporation DisplayPort to DVI Fibre Optic Cable 15 ft 4.5 m 1.35 GB/s
- Consumer Electronics