Tripp Lite
Tripp Lite SMX3000XLRT2UA 3000VA 2700W UPS 2U Rack/Tower
Line-interactive UPS delivers 3000VA/2700W sine-wave output with automatic voltage regulation from 158V to 278V, nine IEC outlets, and optional extended runtime
- International Version230V
- Input ConnectionIEC320-C20
- VA Rating3000VA
- Watts2700W
- Output Voltage230V
- Output Frequency50 / 60Hz
- Line-interactive sine-wave output protects sensitive loads
- AVR corrects brownouts from 158V to 278V without using battery
- 2700W capacity runs full load for 3.9 minutes
- 2U rack/tower form factor fits standard cabinets
- 98% line-mode efficiency lowers heat and energy cost
3000VA 2700W Line-Interactive UPS
The Tripp Lite SMX3000XLRT2UA is a 2U rack/tower uninterruptible power supply delivering 3000VA and 2700W of pure sine-wave output at 230V. It targets server, network and telecom installations that need continuous, clean power during mains disturbances.
Fits 2U rack or tower with IEC C20 input
The unit mounts in a standard 2U rack space or stands as a tower, drawing supply through an IEC320-C20 inlet. Nine IEC outlets — eight C13 and one C19 — distribute protected power to connected loads, while automatic voltage regulation corrects sags from 158V and swells to 278V without using battery capacity. DB-9 and USB ports provide local management connectivity, and an optional SNMPWEBCARD adds network monitoring. The 0.9 power factor and 98% line-mode efficiency reduce heat and operating cost.
Hot-swap battery pack and PowerAlert software
A user-replaceable RBC58-2U battery cartridge restores runtime without shutting down attached equipment. Full-load runtime is 3.9 minutes at 2700W; half-load extends to 11.1 minutes at 1350W. Recharge from 10 to 90 percent completes in under five hours. Bundled PowerAlert software enables automated graceful shutdown and configuration via the HID-compliant USB link, while audible alarms signal startup, power failure, low battery, overload and fault conditions. Surge energy rating is 350 joules.
Privalumai
- Line-interactive sine-wave output protects sensitive loads
- AVR corrects brownouts from 158V to 278V without using battery
- 2700W capacity runs full load for 3.9 minutes
- 2U rack/tower form factor fits standard cabinets
- 98% line-mode efficiency lowers heat and energy cost
Specifikacijos
| Brand | TRIPP LITE |
|---|---|
| Model | SMX3000XLRT2UA |
| International Version | 230V |
| Input Connection | IEC320-C20 |
| VA Rating | 3000VA |
| Watts | 2700W |
| Output Voltage | 230V |
| Output Frequency | 50 / 60Hz |
| Outlets | 9 |
| Outlet Type | 8 C13 outlet(s); 1 C19 outlet(s) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full load runtime (minutes): 3.9 min. (2700w) Half load runtime (minutes): 11.1 min. (1350w) |
| Battery Recharge Time | Less than 5 hours from 10 to 90% |
| Battery Replaceable | RBC58-2U |
| Alarms | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
| Interface Port | DB-9, USB |
| Management Software | PowerAlert |
| Rackmountable | 2U |
| Surge Energy Rating | 350 joules |
| Features | 3kVA / 3000VA / 2700W line interactive 2U rack/tower UPS, Sine Wave 230V output, Corrects brownouts and overvoltages from 158V to 278V 0.9 Power Factor, Interactive LCD interface Extended runtime options up to 2700W 4 post compatible mounting accessories 98% line-mode efficiency, 2 switched load banks USB, RS232, EPO and slot for SNMPWEBCARD option 230V C20 inlet, 8 C13 & 1 C19 outlets |
| Dimensions | 3.50" x 17.50" x 19.50" (H x W x D) |
| Weight | 62.8lbs |
| Package Contents | SMX3000XLRT2UA UPS system PowerAlert Software with USB, Serial & EPO cabling 4 post rackmount installation kit Set of 3 C13/C14 power cables Instruction manual |
| Siuntos svoris | 32.93 kg |
| Pakuotės dydis | 603 × 521 × 229 mm |
Klausimai apie šią prekę
How long will the UPS run my equipment at full 2700W load before the battery is depleted?
The internal battery provides 3.9 minutes of runtime at 2700W; at half load (1350W) it extends to 11.1 minutes.
What audible alarms and heat output should I expect during continuous operation?
An audible alarm signals startup, power failure, low battery, overload and fault conditions; line-mode efficiency is 98%, so waste heat is minimal.
Which management cables or cards must I already have to monitor this UPS over the network?
The unit includes DB-9 and USB ports for local management; network monitoring requires the optional SNMPWEBCARD accessory.