HP J1-800G5AA15 EliteDesk 800 G5 all-in-one PC Core i7-8700 16GB 512GB NVMe 23.8
- All-in-One PC
- All-in-One
Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.
HPE
A 2U rack server with dual 16-core Xeon processors, 256 GB DDR4 memory and 7.68 TB enterprise SSD storage, plus redundant power, 10 Gb Ethernet and iLO 5 management
The HPE ProLiant DL380 Gen10 is a 2U rack server supplied new with a rail kit for enterprise deployment. It ships with dual Xeon Gold 6130 processors, each offering 16 cores at 2.10 GHz with turbo up to 3.70 GHz. The system includes 256 GB of DDR4 memory configured as eight 32 GB modules running at 3200 MHz. Storage comprises 7.68 TB of enterprise SSD capacity across four 1.92 TB 2.5-inch SATA drives managed by a P408i-a controller with 2 GB cache and Smart Storage Battery.
Dual hot-swappable power supplies provide redundancy so a failed unit can be replaced without taking the server offline. Integrated Lights Out 5 enables remote monitoring of thermal sensors and power draw from a separate management network. The Broadcom BCM57416 OCP3 adapter delivers dual-port 10 Gb BASE-T connectivity for high-throughput data movement. Windows Server 2022 Standard is licensed for the 16-core configuration and optimised for physical or lightly virtualised workloads.
The combination of 32 total cores and 256 GB DDR4 supports extended virtualisation sessions and large simultaneous application sets without throttling. Enterprise SATA SSDs and the battery-backed RAID controller maintain consistent write performance and data integrity during prolonged heavy I/O. Redundant power and remote management keep critical services available throughout maintenance windows. Memory and drives are supplied separately and require installation before the server enters production.
| Type | Rack |
|---|
Slide each SSD into a bay until the latch clicks, then configure the RAID array in the P408i-a controller BIOS before installing the operating system.
The Smart Storage Battery on the P408i-a controller typically reaches end of life before the SSDs or power supplies.
The 2U chassis airflow hits its cooling ceiling, causing the fans to ramp to maximum speed to keep CPU temperatures within spec.
Arī šajā sadaļā
Tas pats plaukts, tā pati kase — astoņas kriptovalūtas un kursa fiksēšana uz 30 minūtēm.
Kriptovalūta, kurā maksājat, un valūta, kurā redzat cenas.
Nosūtīts no Jūsu maciņa, noformējot pasūtījumu
Tikai informatīvi — katalogā cenas norādītas ASV dolāros
Neviena valūta neatbilst.
Izvēlieties valodu, kurā vietne sarunājas ar Jums.
Neviena valoda neatbilst.
Pirmo reizi šeit?
Jau ir konts?
Automātiskas atiestatīšanas nav: šis veikals nesūta e-pastus, tāpēc nav arī vienreizējas saites, ko pieprasīt. Atstājiet adresi kontā, un tā tiks apstrādāta manuāli.
Pieprasījums saņemts
Uz Jūsu e-pastu nekas neatnāks — šis veikals vispār nesūta e-pastus. Kāds šos pieprasījumus apstrādā manuāli.
Atcerējāties?