Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.

Uzraudzītās preces Pieteikties

Matrix

Matrix MPS-3035 5-Channel Linear Server Power Supply 30V 3A

SKU CH-2YG8-FK3VM

Five-channel linear supply delivers 30 V at 3 A per channel with 1 mV and 0.1 mA resolution, RS-232 control, nine memory groups, and intelligent fan cooling

  • Single/RedundantMATRIX 5-Channel Programmable Power Supply 30V 3A, MPS-3035
  • Input Frequency Rangenot_applicable
  • +12V RailsMATRIX 5-Channel Programmable Power Supply 30V 3A, MPS-3035
  • PFCMATRIX 5-Channel Programmable Power Supply 30V 3A, MPS-3035
  • Dimensions19 in x 14.6 in x 6 in
  • Weight66 pounds
  • Five isolated channels in one unit simplify multi-rail testing
  • 1 mV and 0.1 mA resolution enable precise voltage and current setting
  • Linear topology delivers low ripple and noise for sensitive loads
  • Nine memory groups store configurations for quick recall
  • RS-232 interface allows automated control and data logging

Five-channel linear supply

The Matrix MPS-3035 delivers five isolated 30 V 3 A channels in a single 19-inch rack unit. Each output can be adjusted independently with 1 mV and 0.1 mA resolution. The unit suits test benches, calibration labs and development rigs that need clean, programmable DC power.

Low-ripple output with smart cooling

Linear regulation keeps ripple and noise to a minimum across all channels. An intelligent fan system adjusts speed according to internal temperature, so acoustic output stays low during typical loads. The 66-pound chassis provides stable thermal mass for extended sessions.

RS-232 control and stored setups

A rear-panel RS-232 port enables remote programming and data logging from a host PC. Nine internal memory groups let operators recall voltage and current presets without re-entering values. No additional cables or software licences are mentioned in the supplied data.

Priekšrocības

  • Five isolated channels in one unit simplify multi-rail testing
  • 1 mV and 0.1 mA resolution enable precise voltage and current setting
  • Linear topology delivers low ripple and noise for sensitive loads
  • Nine memory groups store configurations for quick recall
  • RS-232 interface allows automated control and data logging

Specifikācijas

BrandMATRIX
SeriesMPS-3035
ModelMPS-3035
Part NumberMPS-3035
Single/RedundantMATRIX 5-Channel Programmable Power Supply 30V 3A, MPS-3035 Linear Power Supply 1mV, 0.1mA High Resolution, Variable Power Supply with 9 Groups Data Storage, RS232, Intelligent Fan System, List Output
Input Frequency Rangenot_applicable
+12V RailsMATRIX 5-Channel Programmable Power Supply 30V 3A, MPS-3035 Linear Power Supply 1mV, 0.1mA High Resolution, Variable Power Supply with 9 Groups Data Storage, RS232, Intelligent Fan System, List Output
PFCMATRIX 5-Channel Programmable Power Supply 30V 3A, MPS-3035 Linear Power Supply 1mV, 0.1mA High Resolution, Variable Power Supply with 9 Groups Data Storage, RS232, Intelligent Fan System, List Output
Dimensions19 in x 14.6 in x 6 in
Weight66 pounds
Package ContentsMATRIX 5-Channel Programmable Power Supply 30V 3A, MPS-3035 Linear Power Supply 1mV, 0.1mA High Resolution, Variable Power Supply with 9 Groups Data Storage, RS232, Intelligent Fan System, List Output x 1

Jautājumi par šo preci

How do I rack-mount the MPS-3035 and what clearance does the intelligent fan system need?

The unit measures 19 in wide, 14.6 in deep and 6 in high, fitting a standard 19-inch rack. Leave at least 12 cm free behind the rear exhaust so the intelligent fan system can move air without recirculation.

Which parts of the MPS-3035 will need replacement after extended use?

The internal cooling fan is the only moving component; plan to replace it when bearing noise appears. Electrolytic capacitors on each of the five isolated channels may require service after several years of continuous operation.

What thermal limit appears first when all five channels run at 30 V 3 A continuously?

The intelligent fan system ramps speed as internal temperature rises; sustained full-load output on all channels will hit the thermal-protection threshold first, causing the supply to reduce output or shut down until it cools.