NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.
Mean Well
Delivers 24V at 13A with active PFC, forced-air cooling and full-load burn-in testing
The Mean Well SP-320-24 is a 24V 13A AT-type power supply rated for 312W continuous output. It suits system integrators and maintenance engineers who need a reliable DC source for automation cabinets, test benches or retrofit projects. The universal AC input accepts full-range mains without manual switching. Active PFC reduces harmonic distortion on the supply network.
A built-in DC fan provides forced-air cooling across the chassis. Fan speed control adjusts airflow to load and temperature, limiting acoustic output during lighter duty cycles. The unit has passed a 100% full load burn-in test at the factory. Protection circuits cover short circuit, overload, over voltage and over temperature events.
Remote sense compensation corrects voltage drop across long cable runs to the load. An ON/OFF control input allows external sequencing without interrupting the AC feed. Current sharing supports up to 2400W when up to four compatible units are paralleled. A DC OK signal output simplifies monitoring in supervisory systems.
| Type | AT |
|---|
Mount the unit on a flat metal surface using the four chassis holes to aid heat transfer. The step often missed is connecting the remote-sense leads to the load terminals; without them the 24 V output drops under the 13 A load.
The built-in DC fan with speed control is the only moving component; its bearings typically wear before the electrolytic capacitors, so plan a fan swap after several years of 24/7 use.
Forced-air cooling handles the 312 W load, but if the intake air exceeds the unit's rated ambient temperature the over-temperature protection will shut the output down before any other limit is reached.
Arī šajā sadaļā
Tas pats plaukts, tā pati kase — astoņas kriptovalūtas un kursa fiksēšana uz 30 minūtēm.
Kriptovalūta, kurā maksājat, un valūta, kurā redzat cenas.
Nosūtīts no Jūsu maciņa, noformējot pasūtījumu
Tikai informatīvi — katalogā cenas norādītas ASV dolāros
Neviena valūta neatbilst.
Izvēlieties valodu, kurā vietne sarunājas ar Jums.
Pirmo reizi šeit?
Jau ir konts?
Automātiskas atiestatīšanas nav: šis veikals nesūta e-pastus, tāpēc nav arī vienreizējas saites, ko pieprasīt. Atstājiet adresi kontā, un tā tiks apstrādāta manuāli.
Pieprasījums saņemts
Uz Jūsu e-pastu nekas neatnāks — šis veikals vispār nesūta e-pastus. Kāds šos pieprasījumus apstrādā manuāli.
Atcerējāties?