Fans
Fans D4E225-CC01-39 centrifugal double inlet industrial cooling fan
Centrifugal double-inlet fan runs at 1210 to 1300 rpm on 230 VAC 50/60 Hz for ABB inverter cooling
- Reduces ABB inverter maintenance costs with German ebm-papst engineering
- Dual-voltage 230 VAC operation at 50/60 Hz for global compatibility
- Wide -25 °C to 30 °C ambient range suits harsh industrial sites
- Delivers 540 W / 625 W cooling power at 1210 / 1300 rpm
- 16 µF 400 V capacitor ensures stable motor start-up
Industrial centrifugal fan for inverter cooling
The D4E225-CC01-39 is a new double-inlet centrifugal fan built for industrial cooling duties. It runs on 230 VAC at 50 or 60 Hz and draws 2.4 A at 50 Hz and 2.75 A at 60 Hz. The unit is rated for continuous operation between -25 °C and 30 °C ambient temperature.
Replaces worn inverter cooling fans in heavy
This fan serves as a direct replacement for failed cooling units on ABB drives used in compressors, blowers, cranes, elevators, lifts, winches and cooling towers. The upgrade is worth it when existing fans can no longer maintain the minimum back pressure of 250 Pa at 50 Hz or 300 Pa at 60 Hz, causing drive overheating or tripping.
Limited by fixed-speed AC supply
The motor M4E074-LA operates at a fixed 1210 rpm on 50 Hz and 1300 rpm on 60 Hz with no speed control built in. Power consumption rises from 540 W to 625 W between the two frequencies. A 16 µF, 400 VDB capacitor rated S2 (CE) is required for each frequency and must be matched exactly.
Βασικά χαρακτηριστικά
- Reduces ABB inverter maintenance costs with German ebm-papst engineering
- Dual-voltage 230 VAC operation at 50/60 Hz for global compatibility
- Wide -25 °C to 30 °C ambient range suits harsh industrial sites
- Delivers 540 W / 625 W cooling power at 1210 / 1300 rpm
- 16 µF 400 V capacitor ensures stable motor start-up
Προδιαγραφές
Δεν έχουν δημοσιευτεί ακόμη προδιαγραφές για αυτό το προϊόν.
Ερωτήσεις για αυτό το προϊόν
What back-pressure rating does the D4E225-CC01-39 need to operate correctly?
The fan requires a minimum back pressure of 250 Pa at 50 Hz and 300 Pa at 60 Hz.
Which capacitor must be fitted when installing the M4E074-LA motor?
Fit a 16 µF, 400 VDB capacitor rated to the S2 (CE) standard.
How often should the capacitor be checked or replaced on this centrifugal fan?
Inspect the 16 µF capacitor during routine inverter maintenance; replace it if capacitance drops below spec or the casing shows bulging.
Επίσης σε αυτό το ράφι
Οι πελάτες σύγκριναν και αυτά
Ίδιο ράφι, ίδιο ταμείο — οκτώ νομίσματα και κλείδωμα ισοτιμίας 30 λεπτών.
Lenovo ThinkStation P300 workstation i7-4790 3.6GHz 16GB 180GB K620
- 1
- 16GB