Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.

Hinnavaatlus Logi sisse

APC

APC AP8959 Switched Rack PDU 24-Outlet 0U 20A IEC C20

SKU CH-02YD-KF3HK MPN AP8959

A switched rack PDU with 24 IEC outlets, remote on/off control per outlet, power sequencing, and real-time current metering for 20 A input via IEC C20

  • TypeSwitched
  • Rack Size0U
  • CertificationscUL Listed, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 610
  • ROHSYes
  • Input VoltageNormal Input Voltage: 200V, 208V, 230V Acceptable Input Volt
  • Input Frequency50/60 Hz
  • Remote reboot of individual outlets via switched control
  • 24 locking IEC outlets (21 C13 + 3 C19) fit dense racks
  • Real-time current metering with user-defined overload alarms
  • 0U vertical form factor mounts without using rack units
  • Wide 100–240 V AC input supports global voltage ranges

Switched Rack PDU with 24 Outlets

The APC AP8959 is a zero-U switched power distribution unit built for dense server racks. It delivers 24 locking IEC outlets and remote outlet-level control over Web, SNMP, CLI or Telnet. Network operators and data-centre managers use it to reboot individual devices, sequence startup order and monitor real-time current draw with alarm thresholds.

0U Form Factor for Vertical Mounting

This unit mounts vertically in the zero-U space of a standard rack, leaving all horizontal U positions free for compute gear. It replaces basic non-switched strips that lack remote power cycling, outlet locking or sequenced power-on delays. The upgrade is worth it when you need to reboot hung servers without a site visit or prevent accidental disconnection of critical loads.

20 A Input with 16 A Derated Capacity

The C20 inlet accepts 100–240 V AC at 50/60 Hz and is rated for 20 A maximum input, with a regulatory derated limit of 16 A. Three C19 and twenty-one C13 outlets distribute power to connected equipment. It comfortably handles mixed C13/C19 loads within the 16 A continuous budget; sustained draw above that level will exceed the derated rating and risk tripping upstream protection.

Põhijooned

  • Remote reboot of individual outlets via switched control
  • 24 locking IEC outlets (21 C13 + 3 C19) fit dense racks
  • Real-time current metering with user-defined overload alarms
  • 0U vertical form factor mounts without using rack units
  • Wide 100–240 V AC input supports global voltage ranges

Tehnilised andmed

BrandAPC
SeriesSwitched Rack PDU
ModelAP8959
TypeSwitched
Rack Size0U
CertificationscUL Listed, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, PSE, UL Listed, VDE
ROHSYes
Input VoltageNormal Input Voltage: 200V, 208V, 230V
Acceptable Input Voltage: 100 - 240V AC
Input Frequency50/60 Hz
Maximum Input Current20A
Regulatory Derated Input Current16A
Input Connector(s)IEC-320 C20
Output Voltage100V, 200V, 208V, 230V
Output Connector(s)3 x IEC 320 C19 (Battery Backup)
21 x IEC 320 C13 (Battery Backup)
Overload ProtectionNo
Operating Environment-5 - 45 ºC
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
FeaturesColor: Black
Units per Pallet: 48.0
Output Maximum Total Current Draw: 16
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Curre
Dimensions70.50" x 2.20" x 1.82"
Weight12.60 lbs.
Tarnekaal7.85 kg
Pakendi mõõtmed2007 × 165 × 114 mm

Küsimused selle toote kohta

What rack space does the 0U AP8959 PDU need for vertical mounting?

The 0U form factor mounts vertically in the rack's side channels, requiring no horizontal rack units; allow clearance for the 24 outlets and the IEC C20 input cord.

How is the AP8959 connected to the network for remote outlet switching, and what step is often missed?

Connect the Ethernet cable to the built-in network port, then configure an IP address via the Web UI, SNMP, CLI or Telnet; the step often missed is setting user-defined alarm thresholds for current monitoring.

Which environmental sensor can be added later to the AP8959 for rack-condition monitoring?

A temperature/humidity sensor plugs into the dedicated sensor port on the PDU to provide remote environmental readings alongside power data.

Veel samast osakonnast

Kliendid võrdlesid neid ka

Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.