Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.

Hinnavaatlus Logi sisse

HP

HP ProLiant DL380 Gen9 2U Rack Server E5-2670 v3 12C 2.3GHz 32GB DDR4 2x 500GB SATA B140i

SKU CH-3Q0K-K8RM2

2U rack server with a 12-core Xeon at 2.3 GHz, 32 GB DDR4, dual 500 GB SATA drives and B140i RAID

  • TypeRack
  • Rack Height2U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon E5 v3
  • MAX Processors2
  • ChipsetIntel C610

Installed Memory Size 32GB

HDD 2 x 500GB

  • 12-core Xeon at 2.3 GHz handles multi-threaded workloads
  • 32 GB DDR4 ECC memory supports virtualisation density
  • 2 × 500 GB 7.2 K SATA drives provide baseline storage
  • B140i controller enables RAID 0/1/5/10 without extra hardware
  • Dual 500 W hot-swap power supplies keep the 2U chassis running

Built for dense rack workloads

This 2U HP ProLiant DL380 Gen9 fits eight SFF drive bays in a standard rack footprint. A single Intel Xeon E5-2670 v3 with 12 cores at 2.3 GHz and 32 GB of DDR4 ECC registered memory handles virtualization, database and general-purpose tasks. Redundant hot-swap 500 W power supplies keep the platform running during a supply failure.

Steady throughput under load

The B140i software RAID controller manages the two installed 500 GB 7.2 K SATA drives in RAID 0, 1, 5 or 10 without a dedicated hardware cache. Sustained disk I/O therefore depends on the mechanical drives rather than a buffered write-back. DDR4 memory runs at up to 2400 MT/s per DIMM slot, limited by the processor memory controller, so bandwidth scales predictably as all 24 slots are populated across both CPU sockets.

Choose by controller constraint

The B140i supports SATA drives only; SAS, NVME or hardware RAID acceleration are not available on this controller. Buyers who need hardware RAID with battery-backed cache or who plan to populate bays with SAS or NVME devices must select a different controller option. The Matrox G200eH2 graphics provide basic console output only.

Põhijooned

  • 12-core Xeon at 2.3 GHz handles multi-threaded workloads
  • 32 GB DDR4 ECC memory supports virtualisation density
  • 2 × 500 GB 7.2 K SATA drives provide baseline storage
  • B140i controller enables RAID 0/1/5/10 without extra hardware
  • Dual 500 W hot-swap power supplies keep the 2U chassis running

Tehnilised andmed

BrandHP
SeriesProLiant
ModelProliant DL380 G9
TypeRack
Rack Height2U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon E5 v3
MAX Processors2
ChipsetIntel C610
Installed Memory Size32GB
Memory TypeDDR4
Max Memory Capacity32GB
Memory Features24 DIMM slots, 12 per processor. (4GB/8GB/16GB/32GB/64GB DDR4 up to 2400MT/s ECC Registered, actual memory speed dependent on the processor capability).
Number of Memory Slots24
Storage ControllerB140i Software RAID
HDD InterfaceSATA
SSD (Installed)No
Raid LevelRAID 0/1/5/10
Media DrivesNone
GPU TypeMatrox G200eH2
Video Memory16MB
Remote ManagementiLO Management (standard).
LAN Ports4 x Ports
Expansion SlotsPrimary Riser: 3 PCIe 3.0 Slots (1-3) available: 2x Full-Height Half Length, 1x Half-Lenth Full Height. Optional 3 additional slots (Slot 2 PCIe Riser and dual CPU required).
Operating SystemNo
Compatible/Certified OSMicrosoft Windows Small Business Server 2011/2008, Microsoft Windows Server 2008 R2 SP1/SP2, Microsoft Windows HPC Server 2008 R2, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, Oracle Solaris
Weight63.0000LBS

Selle mudeli teised versioonid

5 veel samast sarjast

Sama seeria, erinev mälumaht, jahutus või taktsagedus — võrrelge enne otsustamist.

Küsimused selle toote kohta

How much power does the dual 500W redundant supply draw under full load?

The server ships with two 500W hot-swap power supplies in a redundant configuration.

Which drive trays and cables are required to populate the remaining six 2.5-inch bays?

The chassis includes eight SFF bays; two are occupied by the installed 500GB drives and trays, so six empty trays with SATA cables are needed for additional drives.

Will the B140i controller recognise SAS drives if I add them later?

The B140i is a SATA-only software RAID controller and does not support SAS devices.

Veel samast osakonnast

Kliendid võrdlesid neid ka

Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.