MINUTEMAN
MINUTEMAN EC1500RTXL2U 1500VA 1350W 120V 2U Rack/Tower Online UPS
Delivers 1500VA/1350W online double-conversion power with pure sine wave output, six controllable NEMA 5-15R outlets, and extended runtime in a 2U rack/tower form factor
- International Version120V
- Input Voltage Range0-160VAC
- Input Frequency50/60Hz +/-6Hz Auto-sensing
- Input ConnectionNEMA 5-15P
- VA Rating1500VA
- Watts1350W
Model EC1500RTXL2U
- EC1500RTXL2U
- EC1000LCD
- EC1000LCD-NC
- EC1000RTXL2U
- EC1000RTXL2UNC
- EC1500LCD
- EC1500LCD-NC
- EC1500RT2U
- EC1500RT2UNC
- EC1500RTXL2UNC
- EC2000LCD
- EC2000LCD-NC
Näita veel 7 konfiguratsiooni
Läbikriipsutatud versioonid on olemas, kuid neid pole siin saadaval.
- True sine wave output protects sensitive equipment
- Online double-conversion topology delivers continuous clean power
- 1500 VA / 1350 W capacity supports demanding loads
- 2U rack/tower form factor fits standard enclosures
- Extended runtime with replaceable BM0070 battery module
Product Identity
The Minuteman EC1500RTXL2U is an online UPS that delivers 1500VA and 1350W of true sine wave power. It protects servers, networking gear and sensitive electronics in rack or tower installations. The 0.9 power factor provides more usable wattage for modern power supplies.
Thermals Noise Power
The unit operates from 0 to 40°C with 10 to 90 percent non-condensing humidity. Online topology continuously conditions incoming power, eliminating transfer time during outages. Input voltage range spans 0 to 160VAC with auto-sensing 50 or 60Hz frequency.
Accessories Software Impact
Six NEMA 5-15R outlets include controllable receptacles for load shedding or scheduled reboots. USB interface enables monitoring and graceful shutdown software integration. Replaceable battery module BM0070 extends service life without replacing the entire UPS.
Põhijooned
- True sine wave output protects sensitive equipment
- Online double-conversion topology delivers continuous clean power
- 1500 VA / 1350 W capacity supports demanding loads
- 2U rack/tower form factor fits standard enclosures
- Extended runtime with replaceable BM0070 battery module
Tehnilised andmed
| Brand | MINUTEMAN |
|---|---|
| Series | ENCOMPASS RTXL |
| Model | EC1500RTXL2U |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/-6Hz Auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500VA |
| Watts | 1350W |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz ±0.2Hz unless synchronized to line |
| Outlets | 6 |
| Outlet Type | (6) NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 15 min Full Load: 5 min |
| Battery Replaceable | BM0070 |
| Approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 /R: 2014), FCC Class A, CE certified, Energy Star 2.0, DoE 10 CFR Part 430, RoHS2 (EU Directive 2011/65/EU) |
| Rackmountable | Yes |
| Temperature | 0° to 40°C (+32° to +104°F) |
| Humidity | 10% to 90% non-condensing |
| Dimensions | 19.2" x 3.5" x 18.9" |
| Weight | 44.1 lbs. |
| Tarnekaal | 20.00 kg |
| Pakendi mõõtmed | 488 × 480 × 89 mm |
Selle mudeli teised versioonid
5 veel samast sarjast
Sama seeria, erinev mälumaht, jahutus või taktsagedus — võrrelge enne otsustamist.
MINUTEMAN EC1000RTXL2UNC UPS 1000VA 900W 120V 6x 5-15R
- 120V
- 0-160VAC
MINUTEMAN EC1500LCD 1500VA 1350W UPS 6 NEMA 5-15R Tower
- 120V
- 0 V AC - 160 V AC
Küsimused selle toote kohta
How do I install the MINUTEMAN EC1500RTXL2U in a rack, and what step is often missed?
Mount the 2U chassis using the included brackets, connect the NEMA 5-15P input to a 120V circuit, then attach equipment to the six NEMA 5-15R outlets. The step often missed is configuring the USB communication link so management software can trigger graceful shutdowns before battery depletion.
Which battery module replaces the internal pack when runtime drops, and how often should I check it?
The BM0070 module replaces the sealed lead-acid pack. Inspect battery health every six months using the front-panel self-test or the USB monitoring software; plan replacement around the three-to-five-year mark depending on temperature and discharge cycles.
What is the first limit reached when the EC1500RTXL2U runs at full 1350W load continuously?
Battery runtime is the first hard limit — five minutes at full load. After that the unit will shut down unless utility power returns. Thermal limits (0° to 40°C ambient) and the 1500VA apparent-power ceiling are not reached before the battery is exhausted.
Veel samast osakonnast
Kliendid võrdlesid neid ka
Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case