MINUTEMAN
MINUTEMAN EC1500RT2UNC 1500VA 1350W 120V 2U Rack/Tower UPS
Online double-conversion UPS delivers 1500VA/1350W pure sine-wave power with six NEMA 5-15R outlets and five minutes full-load runtime
- International Version120V
- Input Voltage Range0-160VAC
- Input Frequency50/60Hz +/-6Hz Auto-sensing
- VA Rating1500VA
- Watts1350W
- Output Voltage120V
Model EC1500RT2UNC
- EC1500RT2UNC
- EC1000LCD
- EC1000LCD-NC
- EC1000RTXL2U
- EC1000RTXL2UNC
- EC1500LCD
- EC1500LCD-NC
- EC1500RT2U
- EC1500RTXL2U
- EC1500RTXL2UNC
- EC2000LCD
- EC2000LCD-NC
Näita veel 7 konfiguratsiooni
Läbikriipsutatud versioonid on olemas, kuid neid pole siin saadaval.
- Double-conversion online topology delivers clean 120 V output with ±0.2 Hz stability
- 1350 W capacity supports critical servers and networking gear through outages
- 5 minutes runtime at full load, 15 minutes at half load
- Hot-swappable sealed lead-acid battery (BM0070) enables zero-downtime replacement
- 2U rack/tower form factor with six NEMA 5-15R outlets and USB, DB-9, SNMP management
2U Rack/Tower UPS
The Minuteman Encompass EC1500RT2UNC is a double-conversion online UPS rated at 1500VA and 1350W with a 0.9 power factor. It delivers pure sine-wave output at 120V to six NEMA 5-15R receptacles, making it suitable for servers, network gear and sensitive electronics that require clean, uninterrupted power.
Installation and common issues
The unit fits a standard 2U rack space or stands as a tower and weighs approximately 45.10 lb, so two people or a lift are recommended for mounting. Communications are handled through DB-9, USB and an installed SNMP card simultaneously, while a dedicated EPO port allows remote emergency shutdown; the only frequent hurdle is configuring the SNMP card for the network before the first power event.
Sustained-load behaviour
At full 1350W load the battery provides five minutes of runtime, extending to fifteen minutes at half load, after which the sealed lead-acid cells require eight hours to reach 90 per cent charge. The double-conversion topology keeps output frequency within ±0.2Hz and voltage stable across the 0-160VAC input range, so connected equipment sees no transfer-time disturbance during extended brownouts or blackouts.
Põhijooned
- Double-conversion online topology delivers clean 120 V output with ±0.2 Hz stability
- 1350 W capacity supports critical servers and networking gear through outages
- 5 minutes runtime at full load, 15 minutes at half load
- Hot-swappable sealed lead-acid battery (BM0070) enables zero-downtime replacement
- 2U rack/tower form factor with six NEMA 5-15R outlets and USB, DB-9, SNMP management
Tehnilised andmed
| Brand | MINUTEMAN |
|---|---|
| Series | ENCOMPASS |
| Model | EC1500RT2UNC |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/-6Hz Auto-sensing |
| VA Rating | 1500VA |
| Watts | 1350W |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz ±0.2Hz unless synchronized to line |
| Outlets | 6 |
| Outlet Type | (6) NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 15 min Full Load: 5 min |
| Battery Recharge Time | 8 hours to 90% from total discharge |
| Battery Replaceable | BM0070 |
| Interface Port | DB-9, USB, RJ-45 |
| Approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class A, CE certified, RoHS2 (EU Directive 2011/65/EU) |
| Surge Energy Rating | 254 Joules |
| Temperature | Operating (max)/Storage Temperature: +32 to +104°F (0 to 40°C) / +14 to +122°F (-10 to +50°C) |
| Humidity | 10% to 90% non-condensing |
| Dimensions | 19.2" x 3.5" x 18.9" |
| Weight | 44.1 lbs. |
| Tarnekaal | 23.13 kg |
| Pakendi mõõtmed | 650 × 544 × 229 mm |
Selle mudeli teised versioonid
5 veel samast sarjast
Sama seeria, erinev mälumaht, jahutus või taktsagedus — võrrelge enne otsustamist.
MINUTEMAN EC1500LCD 1500VA 1350W UPS 6 NEMA 5-15R Tower
- 120V
- 0 V AC - 160 V AC
MINUTEMAN EC1500RTXL2UNC UPS 1500VA 1350W 120V 6x 5-15R
- 120V
- 0-160VAC
MINUTEMAN EC2000LCD 2000VA 1800W On-line Tower UPS 8 Outlets
- 120V
- 0-160VAC
Küsimused selle toote kohta
How do I verify the EC1500RT2UNC is operating correctly after installation?
Check the front-panel LCD for a steady "Online" status and 120 V output; confirm SentryHD software over USB or the installed SNMP card reports 1350 W capacity, 0.9 power factor and battery health; run a self-test from the panel or software to validate the 5-minute full-load runtime.
What ships with the EC1500RT2UNC and what must I purchase separately?
The box contains the 2U rack/tower UPS, SentryHD software media and a pre-installed SNMP communications card; the DB-9, USB and RJ-45 cables for those ports, rack-mount rails and replacement battery cartridge BM0070 are not included.
Which capacity of the ENCOMPASS 1500 VA line should I choose for my load?
This model delivers 1500 VA / 1350 W at 120 V with 5 minutes at full load and 15 minutes at half load; select it when your connected equipment draws up to 1350 W and you need true sine-wave online protection in a 2U form factor.
Veel samast osakonnast
Kliendid võrdlesid neid ka
Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case