Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.

Favoriete artikelen Inloggen

MINUTEMAN

MINUTEMAN EC1500RT2UNC 1500VA 1350W 120V 2U Rack/Tower UPS

SKU CH-YECF-VHY1E MPN EC1500RT2UNC

Online double-conversion UPS delivers 1500VA/1350W pure sine-wave power with six NEMA 5-15R outlets and five minutes full-load runtime

  • International Version120V
  • Input Voltage Range0-160VAC
  • Input Frequency50/60Hz +/-6Hz Auto-sensing
  • VA Rating1500VA
  • Watts1350W
  • Output Voltage120V

Doorgestreepte varianten bestaan wel, maar zijn hier niet op voorraad.

  • Double-conversion online topology delivers clean 120 V output with ±0.2 Hz stability
  • 1350 W capacity supports critical servers and networking gear through outages
  • 5 minutes runtime at full load, 15 minutes at half load
  • Hot-swappable sealed lead-acid battery (BM0070) enables zero-downtime replacement
  • 2U rack/tower form factor with six NEMA 5-15R outlets and USB, DB-9, SNMP management

2U Rack/Tower UPS

The Minuteman Encompass EC1500RT2UNC is a double-conversion online UPS rated at 1500VA and 1350W with a 0.9 power factor. It delivers pure sine-wave output at 120V to six NEMA 5-15R receptacles, making it suitable for servers, network gear and sensitive electronics that require clean, uninterrupted power.

Installation and common issues

The unit fits a standard 2U rack space or stands as a tower and weighs approximately 45.10 lb, so two people or a lift are recommended for mounting. Communications are handled through DB-9, USB and an installed SNMP card simultaneously, while a dedicated EPO port allows remote emergency shutdown; the only frequent hurdle is configuring the SNMP card for the network before the first power event.

Sustained-load behaviour

At full 1350W load the battery provides five minutes of runtime, extending to fifteen minutes at half load, after which the sealed lead-acid cells require eight hours to reach 90 per cent charge. The double-conversion topology keeps output frequency within ±0.2Hz and voltage stable across the 0-160VAC input range, so connected equipment sees no transfer-time disturbance during extended brownouts or blackouts.

Pluspunten

  • Double-conversion online topology delivers clean 120 V output with ±0.2 Hz stability
  • 1350 W capacity supports critical servers and networking gear through outages
  • 5 minutes runtime at full load, 15 minutes at half load
  • Hot-swappable sealed lead-acid battery (BM0070) enables zero-downtime replacement
  • 2U rack/tower form factor with six NEMA 5-15R outlets and USB, DB-9, SNMP management

Specificaties

BrandMINUTEMAN
SeriesENCOMPASS
ModelEC1500RT2UNC
International Version120V
Input Voltage Range0-160VAC
Input Frequency50/60Hz +/-6Hz Auto-sensing
VA Rating1500VA
Watts1350W
Output Voltage120V
Output Frequency50/60Hz ±0.2Hz unless synchronized to line
Outlets6
Outlet Type(6) NEMA 5-15R
Battery TypeSealed Lead Acid
Battery Run TimeHalf Load: 15 min
Full Load: 5 min
Battery Recharge Time8 hours to 90% from total discharge
Battery ReplaceableBM0070
Interface PortDB-9, USB, RJ-45
ApprovalscTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class A, CE certified, RoHS2 (EU Directive 2011/65/EU)
Surge Energy Rating254 Joules
TemperatureOperating (max)/Storage Temperature: +32 to +104°F (0 to 40°C) / +14 to +122°F (-10 to +50°C)
Humidity10% to 90% non-condensing
Dimensions19.2" x 3.5" x 18.9"
Weight44.1 lbs.
Verzendgewicht23.13 kg
Pakketafmetingen650 × 544 × 229 mm

Andere versies van dit model

Nog 5 in dezelfde serie

Dezelfde familie, met ander geheugen, andere koeler of kloksnelheid — vergelijk voordat u beslist.

Vragen over dit artikel

How do I verify the EC1500RT2UNC is operating correctly after installation?

Check the front-panel LCD for a steady "Online" status and 120 V output; confirm SentryHD software over USB or the installed SNMP card reports 1350 W capacity, 0.9 power factor and battery health; run a self-test from the panel or software to validate the 5-minute full-load runtime.

What ships with the EC1500RT2UNC and what must I purchase separately?

The box contains the 2U rack/tower UPS, SentryHD software media and a pre-installed SNMP communications card; the DB-9, USB and RJ-45 cables for those ports, rack-mount rails and replacement battery cartridge BM0070 are not included.