Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

MINUTEMAN

MINUTEMAN EC1500RT2UNC 1500VA 1350W 120V 2U Rack/Tower UPS

SKU CH-YECF-VHY1E MPN EC1500RT2UNC

Online double-conversion UPS delivers 1500VA/1350W pure sine-wave power with six NEMA 5-15R outlets and five minutes full-load runtime

  • International Version120V
  • Input Voltage Range0-160VAC
  • Input Frequency50/60Hz +/-6Hz Auto-sensing
  • VA Rating1500VA
  • Watts1350W
  • Output Voltage120V

De overstregede versioner findes, men er ikke på lager her.

  • Double-conversion online topology delivers clean 120 V output with ±0.2 Hz stability
  • 1350 W capacity supports critical servers and networking gear through outages
  • 5 minutes runtime at full load, 15 minutes at half load
  • Hot-swappable sealed lead-acid battery (BM0070) enables zero-downtime replacement
  • 2U rack/tower form factor with six NEMA 5-15R outlets and USB, DB-9, SNMP management

2U Rack/Tower UPS

The Minuteman Encompass EC1500RT2UNC is a double-conversion online UPS rated at 1500VA and 1350W with a 0.9 power factor. It delivers pure sine-wave output at 120V to six NEMA 5-15R receptacles, making it suitable for servers, network gear and sensitive electronics that require clean, uninterrupted power.

Installation and common issues

The unit fits a standard 2U rack space or stands as a tower and weighs approximately 45.10 lb, so two people or a lift are recommended for mounting. Communications are handled through DB-9, USB and an installed SNMP card simultaneously, while a dedicated EPO port allows remote emergency shutdown; the only frequent hurdle is configuring the SNMP card for the network before the first power event.

Sustained-load behaviour

At full 1350W load the battery provides five minutes of runtime, extending to fifteen minutes at half load, after which the sealed lead-acid cells require eight hours to reach 90 per cent charge. The double-conversion topology keeps output frequency within ±0.2Hz and voltage stable across the 0-160VAC input range, so connected equipment sees no transfer-time disturbance during extended brownouts or blackouts.

Fordele

  • Double-conversion online topology delivers clean 120 V output with ±0.2 Hz stability
  • 1350 W capacity supports critical servers and networking gear through outages
  • 5 minutes runtime at full load, 15 minutes at half load
  • Hot-swappable sealed lead-acid battery (BM0070) enables zero-downtime replacement
  • 2U rack/tower form factor with six NEMA 5-15R outlets and USB, DB-9, SNMP management

Specifikationer

BrandMINUTEMAN
SeriesENCOMPASS
ModelEC1500RT2UNC
International Version120V
Input Voltage Range0-160VAC
Input Frequency50/60Hz +/-6Hz Auto-sensing
VA Rating1500VA
Watts1350W
Output Voltage120V
Output Frequency50/60Hz ±0.2Hz unless synchronized to line
Outlets6
Outlet Type(6) NEMA 5-15R
Battery TypeSealed Lead Acid
Battery Run TimeHalf Load: 15 min
Full Load: 5 min
Battery Recharge Time8 hours to 90% from total discharge
Battery ReplaceableBM0070
Interface PortDB-9, USB, RJ-45
ApprovalscTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class A, CE certified, RoHS2 (EU Directive 2011/65/EU)
Surge Energy Rating254 Joules
TemperatureOperating (max)/Storage Temperature: +32 to +104°F (0 to 40°C) / +14 to +122°F (-10 to +50°C)
Humidity10% to 90% non-condensing
Dimensions19.2" x 3.5" x 18.9"
Weight44.1 lbs.
Forsendelsesvægt23.13 kg
Pakkestørrelse650 × 544 × 229 mm

Andre versioner af denne model

5 flere i samme serie

Samme familie, men med anden hukommelse, køler eller clockfrekvens — sammenlign, før du bestemmer dig.

Spørgsmål om denne vare

How do I verify the EC1500RT2UNC is operating correctly after installation?

Check the front-panel LCD for a steady "Online" status and 120 V output; confirm SentryHD software over USB or the installed SNMP card reports 1350 W capacity, 0.9 power factor and battery health; run a self-test from the panel or software to validate the 5-minute full-load runtime.

What ships with the EC1500RT2UNC and what must I purchase separately?

The box contains the 2U rack/tower UPS, SentryHD software media and a pre-installed SNMP communications card; the DB-9, USB and RJ-45 cables for those ports, rack-mount rails and replacement battery cartridge BM0070 are not included.

Which capacity of the ENCOMPASS 1500 VA line should I choose for my load?

This model delivers 1500 VA / 1350 W at 120 V with 5 minutes at full load and 15 minutes at half load; select it when your connected equipment draws up to 1350 W and you need true sine-wave online protection in a 2U form factor.

Også på denne hylde

Kunderne har også sammenlignet disse

Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.