Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.

Praćeni artikli Prijava

APC

APC BR1500MS2 UPS 1500VA/900W 120V 10 Outlets LCD USB A+C

SKU CH-ZKT2-H8T0E MPN BR1500MS2

Provides 1500 VA battery backup with sine-wave output, 10 NEMA 5-15R outlets, USB A and C charging, AVR, coaxial and Ethernet surge protection, and a user-replaceable lead-acid battery

  • International Version120V
  • Input Voltage Range88 - 147V
  • Input Frequency60 Hz +/- 3 Hz
  • Input ConnectionNEMA 5-15P
  • VA Rating1500 VA
  • Watts900W

VA 1500 VA

  • 1500VA/900W capacity keeps critical devices running during outages
  • 6 battery-backup outlets + 4 surge-only outlets protect every connected device
  • 1080-joule surge rating shields electronics from damaging voltage spikes
  • USB Type-A and Type-C ports charge phones and tablets without extra adapters
  • LCD screen shows real-time power status and battery health at a glance

What this UPS protects

The BR1500MS2 is a 1500 VA tower battery backup that delivers 900 W of sine-wave output to desktop PCs, networking gear, external drives and game consoles. It supplies clean power during outages and shields connected equipment from voltage spikes and data-line surges. Home-office users and small-business workstations get uninterrupted runtime for safe shutdown.

Deciding specification: 900 watt capacity

The single figure that determines fit is the 900 W rated output. Add the maximum power draw of every device you will plug into the six battery-backup outlets; if the total exceeds 900 W the unit will overload and shut down. Equipment needing more continuous power requires a higher-capacity UPS.

Behaviour under sustained load

At full 900 W load the battery provides 4.10 minutes of runtime, enough for an orderly shutdown but not for extended operation. At half load runtime extends to 14.50 minutes. After a discharge the sealed lead-acid battery needs 16 hours to reach full charge again, so repeated outages within a day will reduce available backup time.

Istaknuto

  • 1500VA/900W capacity keeps critical devices running during outages
  • 6 battery-backup outlets + 4 surge-only outlets protect every connected device
  • 1080-joule surge rating shields electronics from damaging voltage spikes
  • USB Type-A and Type-C ports charge phones and tablets without extra adapters
  • LCD screen shows real-time power status and battery health at a glance

Specifikacije

BrandAPC
ModelBR1500MS2
International Version120V
Input Voltage Range88 - 147V
Input Frequency60 Hz +/- 3 Hz
Input ConnectionNEMA 5-15P
VA Rating1500 VA
Watts900W
Output Voltage120V
Output Frequency60 Hz +/- 3 Hz
Outlets10
Outlet Type4 x NEMA 5-15R (Surge Protection)
6 x NEMA 5-15R (Battery Backup)
Battery TypeLead Acid Battery
Battery Run TimeBackup/Run Time (Half Load) 14.50 Minute
Backup/Run Time (Full Load) 4.10 Minute
Battery Recharge Time16 hour(s)
AlarmsAlarm when on battery: distinctive low battery alarm: overload continuous tone alarm
ApprovalsENERGY STAR V2.0 (USA), FCC part 15 class B, NOM, TUV C-US certified
Data Line ProtectionCoaxial cable for CATV/SATV/modem/audio-video, RJ45 10/100/1000 Base-T Ethernet protection
Surge Energy Rating1080 Joules
Dimensions10.24" x 3.94" x 14.49"
Weight27.56 lbs.
VA1500 VA
WattN/A
OptionsNo
Težina pošiljke14.17 kg
Dimenzije pakiranja482 × 359 × 223 mm

Druge verzije ovog modela

još 2 u istoj seriji

Ista obitelj, različita memorija, hladnjak ili frekvencija — usporedite prije kupnje.

Pitanja o ovom artiklu

How long will the 900 W rating keep a typical desktop and monitor running during an outage?

At full 900 W load the unit provides 4.10 minutes of battery backup; at half load it extends to 14.50 minutes.

What does the USB Type A + C port actually do for my devices?

The two USB ports supply smart charging for phones, tablets and other USB powered gear while the UPS is on mains or battery power.

Will the 10.24 x 3.94 x 14.49 inch tower fit on a standard desk shelf?

The unit measures 10.24 inches wide, 3.94 inches deep and 14.49 inches high, so check your shelf clearance against those dimensions.

Također u ovoj kategoriji

Kupci su usporedili ovo

Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.