Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.

Praćeni artikli Prijava

CyberPower

CyberPower M750L Medical Grade UPS 750VA 600W 120V 6 Outlet Tower

SKU CH-6K0T-BA5VM MPN M750L

Medical-grade battery backup provides 600 W runtime with hospital-grade outlets, automatic voltage regulation and a sealed LCD panel tested to UL 60601-1

  • International Version120V
  • Input Voltage Range90 - 150V
  • Input Frequency57 - 63 Hz
  • Input Connection5-15P-HG
  • VA Rating750 VA
  • Watts600 Watts

Options M750L

  • Medical-grade safety with UL 60601-1 testing
  • 750 VA / 600 W backup for critical devices
  • Six hospital-grade outlets with isolation transformer
  • Sealed LCD panel resists spray and debris
  • 30 minutes runtime at half load

Medical-Grade UPS for Patient Care

The CyberPower M750L is a battery backup designed for sensitive medical equipment in hospitals and healthcare facilities. It delivers 750 VA and 600 Watts of clean 120V power through six hospital-grade NEMA 5-15R-HG outlets. The unit has been tested to UL 60601-1 standards for use in patient-care vicinities.

Thermals Noise and Power Management

Automatic voltage regulation corrects input fluctuations between 90 and 150V without using battery reserves. The sealed lead-acid battery provides 30 minutes of runtime at half load and 12 minutes at full load, recharging in under eight hours. A spray-resistant LCD panel displays status while resisting dirt and debris in clinical environments.

Build Integration and Expandability

The tower UPS connects via a hospital-grade 5-15P-HG plug and includes USB and serial ports for PowerPanel Business Edition management. An open SNMP slot accepts an optional RMCARD205 for remote network monitoring. User-replaceable batteries extend service life, while the tip-resistant mini-tower form factor fits securely on medical carts or shelves.

Istaknuto

  • Medical-grade safety with UL 60601-1 testing
  • 750 VA / 600 W backup for critical devices
  • Six hospital-grade outlets with isolation transformer
  • Sealed LCD panel resists spray and debris
  • 30 minutes runtime at half load

Specifikacije

BrandCyberPower Systems (USA)
SeriesMedical Grade UPS
ModelM750L
International Version120V
Input Voltage Range90 - 150V
Input Frequency57 - 63 Hz
Input Connection5-15P-HG
VA Rating750 VA
Watts600 Watts
Output Voltage120Vac +/- 5%
Output Frequency60 Hz +/- 1%
Outlets6
Outlet Type5-15R-HG
Battery TypeSealed Lead Acid
Battery Run TimeAt Half Load: 30 Minutes
At Full Load: 12 Minutes
Battery Recharge Time<8 Hours
Interface PortUSB, Serial
Management SoftwarePowerPanel Business Edition
ApprovalsUL1778 (USA)
Tested to CSA (Canada)
FCC Part 15 Class A (EMI)
UL60601-1 tested (medical grade)
RoHS Compliant
Surge Energy Rating1445 Joules
FeaturesBattery Backup
Surge Protection
Line Interactive Topology
Automatic Voltage Regulation (AVR)
UL 60601-1 Tested
Hospital-Grade Plugs & Outlets
Isolation Transformer
Sealed LCD Screen
Multifunction LCD Panel
Ultra Quiet Design
Replaceable Batteries
Connected Equipment Guarantee
Dimensions8.70" x 6.70" x 17.00"
Weight52.80 lbs.
Package ContentsUPS System, User Manual, USB A+B Type Cable, Serial Cable
Težina pošiljke25.86 kg
Dimenzije pakiranja572 × 349 × 286 mm

Druge verzije ovog modela

još 2 u istoj seriji

Ista obitelj, različita memorija, hladnjak ili frekvencija — usporedite prije kupnje.

Pitanja o ovom artiklu

How do I connect the hospital-grade 5-15P-HG plug and what is the common mistake?

Plug the 5-15P-HG into a grounded 120 V receptacle rated 15 A; the step often missed is verifying the outlet is on a dedicated branch circuit so the UPS does not share capacity with other loads.

When will the sealed lead-acid batteries need replacement and how is it done?

Expect 3–5 years before runtime drops below the rated 30 minutes at half load; the batteries are user-replaceable — power down, open the battery door, disconnect the old pack, insert the new one, and close the door.

What limits continuous operation when the UPS runs at the full 600 W rating?

Battery runtime is 12 minutes at 600 W; after that the unit shuts down, so sustained full-load operation is limited by the 12-minute reserve unless utility power returns.