BFKK 3U Rackmount Server Chassis EATX/ATX/MATX 4x5.25 6x3.5 Top/Side Cooling
- Rackmount
Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.
DELL
A 750 W server power supply accepting 120 V or 230 V AC input, compatible with PowerEdge R630, R640, R730, R730XD, R740 and R740XD rack servers
This Dell KNHJV unit delivers 750 W of power for compatible Dell PowerEdge rack servers. It is designed for IT administrators maintaining or expanding enterprise server infrastructure. The supply accepts 120 V AC and 230 V AC input, making it suitable for standard data-centre power distribution.
The power supply operates from 120 V AC or 230 V AC mains input and provides up to 750 W of output power to the server. Internal cooling is managed by the server chassis airflow, so acoustic and thermal performance depend on the host system configuration. No separate fan or thermal specifications are provided for the module itself.
This module fits Dell PowerEdge R630, R640, R730, R730XD, R740 and R740XD rack servers. It occupies a standard hot-plug power-supply bay and requires no additional cabling beyond the server backplane connection. Builders needing redundant power should verify the server supports multiple units, while those using non-Dell chassis or different PowerEdge models cannot use this supply.
| Brand | DELL |
|---|---|
| Type | Power Supply |
Slide the unit into the hot-plug bay until the latch clicks; the step often missed is verifying the green AC-OK LED lights on both the module and the system LCD to confirm full seating.
Periodically vacuum the intake mesh to prevent dust buildup on the internal fan; the fan assembly is the only field-replaceable component and should be swapped if bearing noise appears.
The 750 W output ceiling is reached first; once the combined rail draw hits 750 W the unit enters over-current protection and shuts down until the load drops.
Također u ovoj kategoriji
Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.
Ono što šaljete, i ono u čemu gledate cijene.
Poslano iz Vašeg novčanika na blagajni
Samo prikaz — katalog je izražen u dolarima
Nijedna valuta ne odgovara.
Odaberite jezik na kojem Vam se stranica obraća.
Nema odgovarajućeg jezika.
Novi ste ovdje?
Već imate račun?
Ne postoji automatsko resetiranje: ova trgovina ne šalje e-poštu, stoga ne postoji jednokratna poveznica koju biste mogli zatražiti. Ostavite adresu uz svoj račun, netko će je ručno obraditi.
Zahtjev zaprimljen
Ništa neće stići u Vaš pretinac e-pošte — ova trgovina uopće ne šalje e-poštu. Netko će to ručno preuzeti.
Sjetili ste se?