Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.

Praćeni artikli Prijava

ICY DOCK

ICY DOCK ToughArmor MB092VK-B 2-Bay 2.5 U.2/U.3 NVMe Rack Server

SKU CH-YM6B-CTSER

Holds two 2.5 U.2/U.3 NVMe SSDs in an external 3.5 bay with PCIe 4.0 64Gbps speed, 25mm cooling fan, eagle-hook latch and 2-segment key lock

  • TypeRack
  • Fits 2x 2.5 U.2/U.3 NVMe SSDs from 5-9.5mm height
  • Installs into standardized external 3.5 device bay
  • Uses 2x Slimline SAS SFF-8654 4i connectors per SFF-9402 Rev 1.1
  • Supports NVMe 4.0 64Gbps transfer rates per drive bay
  • Built-in 25mm cooling fan with ventilation holes disperses heat

Drive Bay Compatibility

The ICY DOCK ToughArmor MB092VK-B is a server rack enclosure that fits two 2.5-inch U.2 or U.3 NVMe solid-state drives with heights from 5 mm to 9.5 mm. It installs directly into a standard external 3.5-inch device bay, bringing high-speed storage to the front panel for quick access. The unit uses two Slimline SAS SFF-8654 4i connectors with pinout defined by SFF-9402 Rev 1.1 to deliver NVMe 4.0 transfer rates up to 64 Gbps per drive bay.

Security And Environment Fit

This enclosure suits administrators who need physical drive security in demanding locations. The eagle-hook tray latch and two-segment key lock prevent unauthorised removal, while full-metal construction withstands harsh conditions. Builders whose chassis lack a 3.5-inch front bay or who require internal-only mounting should look at alternative form factors. Users without Slimline SAS host connectors cannot connect the backplane.

Interface And Speed Limit

Each drive bay connects via a Slimline SAS SFF-8654 4i link limited to NVMe 4.0 64 Gbps throughput. The host system must provide matching connectors and PCIe 4.0 lanes to reach that ceiling; slower host interfaces will reduce performance proportionally.

Istaknuto

  • Fits 2x 2.5 U.2/U.3 NVMe SSDs from 5-9.5mm height
  • Installs into standardized external 3.5 device bay
  • Uses 2x Slimline SAS SFF-8654 4i connectors per SFF-9402 Rev 1.1
  • Supports NVMe 4.0 64Gbps transfer rates per drive bay
  • Built-in 25mm cooling fan with ventilation holes disperses heat

Specifikacije

TypeRack

Pitanja o ovom artiklu

How loud or hot does the 25 mm cooling fan run when both U.2 NVMe drives operate continuously?

The built-in 25 mm fan and ventilation holes are designed to disperse heat from the U.2 NVMe SSDs during sustained operation.

Which cables and host connectors must I already have to connect the two Slimline SAS SFF-8654 4i ports?

You need two Slimline SAS SFF-8654 4i cables and a host adapter or motherboard with matching SFF-8654 4i ports compliant with SFF-9402 Rev 1.1 pinout.

Will my existing M.2 NVMe SSDs work in this rack without changes?

M.2 NVMe SSDs require the separate EZConvert MB705M2P-B adapter to convert them to U.2 form factor before they can be installed in the trays.

Također u ovoj kategoriji

Kupci su usporedili ovo

Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.