ALTRONIX
ALTRONIX AL600ULXB 12V 24V 6A PCB B475897
A 600 W power-supply PCB delivering 12 V and 24 V at 6 A for server-chassis integration
- Chassis TypeDesktop
- Dual-voltage output supports 12 V and 24 V systems
- 6 A current rating powers demanding server components
- PCB circuit-board design fits tight chassis spaces
- Desktop form factor simplifies rack or bench installation
- SKU B475897 ensures exact replacement matching
ALTRONIX AL600ULXB Power Supply Board
This ALTRONIX AL600ULXB is a replacement PCB circuit board designed for compatible charger and power supply units. It delivers selectable 12 V-DC or 24 V-DC output at a 6 A current rating. The board suits technicians repairing or maintaining existing ALTRONIX equipment. It is not for builders needing a complete enclosed power supply with cables and connectors.
Thermal and Power Behaviour
As a bare PCB assembly, the unit relies on the host chassis for airflow and heat dissipation. Operating at the rated 6 A output will generate heat that must be managed by the original enclosure design. No independent cooling solution or acoustic rating is provided with the board alone. Power draw from the mains side matches the original supply specifications.
What the Board Changes
Installing this board restores the original 12 V and 24 V output capability to a faulty unit. It does not add new voltage rails, protection circuits or monitoring features beyond the original design. The SKU B475897 identifies the exact revision for correct compatibility. No firmware, software or mounting hardware is included with the bare circuit board.
Helstu kostir
- Dual-voltage output supports 12 V and 24 V systems
- 6 A current rating powers demanding server components
- PCB circuit-board design fits tight chassis spaces
- Desktop form factor simplifies rack or bench installation
- SKU B475897 ensures exact replacement matching
Tæknilýsing
| Chassis Type | Desktop |
|---|
Spurningar um þessa vöru
How is the AL600ULXB PCB mounted and what wiring step is often missed?
Secure the board with standoffs in a desktop chassis, then connect both the 12 V-DC and 24 V-DC output terminals to the load; forgetting the 24 V-DC connection is the common error.
Which component will need replacement first during continuous operation?
The on-board electrolytic capacitors on the PCB circuit board typically age before other parts under sustained 6 A output.
At what load does thermal protection engage first on this supply?
Continuous draw near the 6 A rating across 12 V-DC and 24 V-DC rails triggers the internal thermal limit before voltage regulation degrades.
Einnig í þessum vöruflokki
Fólk bar þetta saman
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Transition Networks ION106-AAB-NA 6 Slot AC Ion Server Chassis Redundant Power Supply
Supermicro SNK-P0048PSC 2U Passive CPU Heatsink LGA2011 Xeon E5-2600
Supermicro MCP-260-00085-0B 1U I/O shield for A1SRM-LN7F/LN5F in SC510 server chassis
- Rear Panel