Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

APC

APC SRT3000XLT 3000 VA 2700 W 208V UPS

SKU CH-GHSY-FC00A MPN SRT3000XLT

Double-conversion on-line UPS delivers 3000 VA and 2700 W at 208 V with three locking outlets and extended-runtime capability

  • International Version208V
  • Input Frequency40 - 70 Hz (auto sensing)
  • Input ConnectionNEMA L6-20P
  • VA Rating3000 VA
  • Watts2700 Watts
  • Output Voltage208V
  • Double-conversion online topology protects critical loads
  • 3000 VA and 2700 W capacity supports dense server racks
  • 208 V input and output matches data-centre power distribution
  • Three locking outlets: two L6-20R and one L6-30R
  • Battery recharges in 3 hours for faster recovery

3000 VA 208V On-Line UPS

The APC Smart-UPS SRT3000XLT delivers 3000 VA and 2700 watts of true double-conversion on-line power protection at 208 volts. It accepts a NEMA L6-20P input and provides three outlets: one NEMA L6-30R and two NEMA L6-20R. The unit includes RJ-45 serial, SmartSlot, and USB interface ports for management integration.

Replaces Standby or Line-Interactive Units

Moving from a standby or line-interactive UPS to this double-conversion topology is worth it when connected equipment requires continuous power conditioning with zero transfer time. The on-line architecture isolates loads from input anomalies including wide voltage swings and frequency variation. Extended-runtime capability allows adding matching battery packs when runtime must be measured in hours rather than minutes.

2700-Watt Load Capacity and Scalable Runtime

The 2700-watt rating comfortably handles dense server, networking, medical, or light-industrial loads within a rack/tower convertible chassis. Runtime scales by attaching external battery packs to meet aggressive backup requirements. The 340-joule surge energy rating and auto-sensing 40–70 Hz input frequency support operation in demanding power environments. Recharge time is three hours.

Helstu kostir

  • Double-conversion online topology protects critical loads
  • 3000 VA and 2700 W capacity supports dense server racks
  • 208 V input and output matches data-centre power distribution
  • Three locking outlets: two L6-20R and one L6-30R
  • Battery recharges in 3 hours for faster recovery

Tæknilýsing

BrandAPC
SeriesSmart-UPS
ModelSRT3000XLT
International Version208V
Input Frequency40 - 70 Hz (auto sensing)
Input ConnectionNEMA L6-20P
VA Rating3000 VA
Watts2700 Watts
Output Voltage208V
Output Frequency50/60 Hz +/- 3 Hz
Outlets3
Outlet Type2 x NEMA L6-20R
1 x NEMA L6-30R
Battery Recharge Time3 Hour(s)
AlarmsAudible and visible alarms prioritized by severity
Interface PortRJ-45 Serial, SmartSlot, USB
Management SoftwareYES
ApprovalscUL Listed, ENERGY STAR (USA), FCC Part 15 Class A, UL 1778
Surge Energy Rating340 Joules
FeaturesAPC Smart-UPS On-Line,2700 Watts / 3000 VA,Input 208V /Output 208V, Interface Port RJ-45 Serial, SmartSlot, USB, Extended runtime model
Dimensions17.00" x 3.35" x 25.00"
Weight69.00 lbs.
Package ContentsSRT3000XLT, CD with software, Documentation CD, Installation guide, Removable support feet, USB cable, Warranty card
Sendingarþyngd63.50 kg
Stærð sendingar980 × 603 × 347 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

What rack space does the 17.00" x 3.35" x 25.00" chassis need?

The unit is 3.35 inches high, which equals 2U of rack space, and 17.00 inches wide by 25.00 inches deep for tower or rack mounting.

Which cable goes into the NEMA L6-20P inlet during setup?

Connect a 208 V supply cord with a matching NEMA L6-20P plug to the single input receptacle; the step often missed is verifying the branch circuit is rated for 20 A before powering on.

When should the internal battery be replaced?

Plan replacement after roughly 3 to 5 years of service; the UPS will sound audible and visible alarms when the battery reaches end of life, and recharge takes 3 hours after a full discharge.