Thermalright MC-2 ARGB Memory Cooler White 3200 RPM
- Fan & Heatsinks
- DDR/DDR2/DDR3/DDR4/…
Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.
Bitspower
A four-pack of G1/4" brass multi-link compression fittings designed for 12mm OD rigid tubing
This four-pack of G1/4" compression fittings is built for custom liquid-cooling loops that use 12mm outer-diameter rigid tubing. The multi-link design lets builders extend runs or bridge components without extra adapters. Machined from high-quality brass, each fitting is engineered for a secure, leak-free seal when assembled correctly. The silver finish matches common loop aesthetics.
As passive brass components, the fittings add no active heat, noise or power draw to the system. They simply conduct coolant between blocks, radiators and reservoirs at whatever temperature and flow rate the loop provides. Correct torque during installation ensures zero leakage under normal operating pressure. No electrical connection or control software is involved.
Supplying four fittings in one package covers the most common multi-link extension scenarios — such as parallel GPU blocks, distribution plates or reservoir top ports — without separate purchases. The RoHS-compliant brass construction keeps material quality consistent across all connection points. Buyers who need different tube diameters, angled rotary joints or coloured accents will need separate fittings not included here.
| Type | Fittings |
|---|
Slide the compression ring and nut onto the tube, insert the tube fully into the fitting body until it seats against the internal stop, then tighten the nut by hand plus a quarter turn with a wrench; the step most often missed is not pushing the tube all the way to the stop before tightening.
Inspect the internal O-rings annually for hardening or cracking and replace them if any coolant weep appears; the brass bodies and compression rings do not wear out under normal use.
The practical limit is the combined length of rigid tubing runs; each additional fitting adds a potential leak path and flow restriction, so long multi-link chains should be pressure-tested thoroughly before final fill.
Einnig í þessum vöruflokki
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Það sem þú greiðir í, og það sem þú sérð verð í.
Sent úr veskinu þínu í greiðsluferlinu
Aðeins til skýringar — verð í vörulistanum eru í Bandaríkjadölum
Enginn gjaldmiðill passar við það.
Veldu tungumálið sem síðan talar við þig á.
Fyrsta heimsókn?
Áttu þegar aðgang?
Það er engin sjálfvirk endurstilling: þessi verslun sendir engan tölvupóst, svo það er enginn einnota tengill til að biðja um. Skildu netfangið eftir á aðganginum og einhver sinnir því handvirkt.
Beiðni skráð
Ekkert er á leiðinni í pósthólfið þitt — þessi verslun sendir engan tölvupóst. Einhver sinnir þessu handvirkt.
Mundir þú það?