HP 27 All-in-One PC AMD Ryzen 5 5500U 16 GB 512 GB 27-cb0060
- 27"
Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.
DELL
A 2U rack server with dual 14-core 2.6GHz CPUs, 128GB DDR4, six 300GB 10K SAS drives and H730P RAID plus iDRAC9 Enterprise remote management
This Dell PowerEdge R740 is a 2U rack server equipped with two Intel Gold 6132 processors, each running at 2.6 GHz with 14 cores. It includes 128 GB of DDR4 memory across eight 16 GB modules operating at 2666 MT/s. Six 300 GB 10K SAS drives and an H730P RAID controller provide the primary storage subsystem.
The dual 14-core CPUs and 128 GB of memory fit virtualisation hosts and database servers that need strong multi-threaded performance. The eight 2.5-inch drive bays limit raw capacity, so buyers who need more storage bays should consider a different chassis. Workloads demanding PCIe Gen 4 bandwidth or newer instruction sets are not supported by this platform.
The installed storage consists of six 300 GB 10K SAS drives managed by the H730P controller. This capacity and spindle speed determine whether the server can hold the required working set without adding drives. If the application needs more space or a different drive interface, the configuration will not match the requirement.
| Brand | DELL |
|---|---|
| Model | R740 |
| Type | Rack |
| Rack Height | 2U |
| CPU Type | Intel |
| Installed Memory Size | 128GB |
| Hard Drive (Installed) | 6x 300GB 10K SAS |
| Storage Controller | H730P |
| Max HDD Capacity | 8x 2.5" Drive Bays |
| Remote Management | iDRAC9 Enterprise |
Yes, the R740 is a 2U rack server that occupies 8x 2.5" drive bays in a standard 19-inch cabinet.
Populate all 16 DIMM slots evenly across both processors; the common mistake is filling only one CPU's channels and leaving half the memory invisible.
Treat the 1100W PSUs and 10K SAS drives as field-replaceable units; swap a PSU immediately on fault LED, and schedule drive replacement after SMART warnings or RAID rebuild events.
Einnig í þessum vöruflokki
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Það sem þú greiðir í, og það sem þú sérð verð í.
Sent úr veskinu þínu í greiðsluferlinu
Aðeins til skýringar — verð í vörulistanum eru í Bandaríkjadölum
Enginn gjaldmiðill passar við það.
Veldu tungumálið sem síðan talar við þig á.
Ekkert tungumál fannst.
Fyrsta heimsókn?
Áttu þegar aðgang?
Það er engin sjálfvirk endurstilling: þessi verslun sendir engan tölvupóst, svo það er enginn einnota tengill til að biðja um. Skildu netfangið eftir á aðganginum og einhver sinnir því handvirkt.
Beiðni skráð
Ekkert er á leiðinni í pósthólfið þitt — þessi verslun sendir engan tölvupóst. Einhver sinnir þessu handvirkt.
Mundir þú það?