Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

DELL

DELL PowerEdge T440 5U rack server 2x Xeon Gold 5118 2.3GHz 12-core 256GB DDR4 H330 8x 2.5" trays 2x 750W PSU

SKU CH-NDEP-3WNF4

5U rack server with dual 12-core Xeon Gold 5118 CPUs at 2.3 GHz, 256 GB DDR4, PERC H330 controller, eight 2.5-inch drive trays and redundant 750 W power supplies

  • TypeRack
  • Rack Height5U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon
  • CPU Speed2.3GHz (3.2GHz Turbo)
  • CPU SocketLGA 3647
  • Dual 12-core Xeon Gold 5118 CPUs at 2.3 GHz deliver 24 threads for heavy workloads
  • 256 GB DDR4-2400 ECC registered memory across 16 slots supports large datasets
  • PERC H330 12 Gb/s SAS/SATA controller manages up to 16 hot-swap 2.5" drive bays
  • Redundant 750 W platinum hot-swap power supplies keep the system running during a failure
  • iDRAC 9 Express provides remote lifecycle management from any browser

Enterprise 5U Tower Server

The Dell PowerEdge T440 is a 5U tower server that accepts an optional rack conversion kit. It ships with two Intel Xeon Gold 5118 processors, each running at 2.3 GHz with a 3.2 GHz turbo frequency and twelve cores. The system includes 256 GB of DDR4-2400 ECC registered memory across eight 32 GB modules and a PERC H330 storage controller.

Virtualisation and Database Hosts

This server suits organisations deploying VMware ESXi, Microsoft Hyper-V or Proxmox VE clusters, as well as Microsoft SQL Server and Linux database workloads. It also fits file and print services, backup targets and software-defined storage nodes. Buyers who need GPU-accelerated compute or front bezel and ready rails included should look at other configurations.

Sixteen-Bay 2.5-Inch Chassis

The chassis provides sixteen hot-swap 2.5-inch drive bays supporting SAS, SATA and SSD media, though only eight drive trays are supplied. This bay count determines how many drives you can install for capacity or redundancy. Verify that eight trays meet your immediate array plans or budget for additional trays separately.

Helstu kostir

  • Dual 12-core Xeon Gold 5118 CPUs at 2.3 GHz deliver 24 threads for heavy workloads
  • 256 GB DDR4-2400 ECC registered memory across 16 slots supports large datasets
  • PERC H330 12 Gb/s SAS/SATA controller manages up to 16 hot-swap 2.5" drive bays
  • Redundant 750 W platinum hot-swap power supplies keep the system running during a failure
  • iDRAC 9 Express provides remote lifecycle management from any browser

Tæknilýsing

BrandDELL
SeriesPowerEdge
ModelT440
TypeRack
Rack Height5U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon
CPU Speed2.3GHz (3.2GHz Turbo)
CPU SocketLGA 3647
Number of CPU Cores12 Core-Processors
CPU FeaturesGold 5118
# of Processors Installed2
MAX Processors2
Installed Memory Size256GB
Memory TypeDDR4
Max Memory Capacity1TB
Number of Memory Slots16
Hard Drive (Installed)None
Storage ControllerDell Perc H330 Controller
SSD (Installed)No
Raid LevelRAID 0/1/5/10/50
Ethernet ControllerIntegrated Dell 2x1GbE Dual Port Ethernet Adapter
Remote ManagementiDRAC9 Express
LAN Ports2 x Ports
Management PortRJ 45
Operating SystemNo

Spurningar um þessa vöru

How do I install the 256 GB DDR4 memory kit into the 16 DIMM slots of the PowerEdge T440?

Populate the eight 32 GB modules in matched pairs across the two CPU channels, following the silkscreen sequence on the board; the step most often missed is seating both latches fully before powering on.

When will the PERC H330 controller or its cache battery need replacement under normal operation?

The H330 has no onboard cache battery to service; plan to replace the controller only if firmware updates cease or a drive-array error persists after cable reseat.

What thermal limit appears first when both Xeon Gold 5118 CPUs run at 3.2 GHz turbo continuously?

The 750 W platinum power supplies hit their sustained-output ceiling before the CPU package temperature reaches its throttle point.

Einnig í þessum vöruflokki

Fólk bar þetta saman