Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

HP

HP ProLiant DL160 Gen9 1U rack server E5-2603v3 1.6GHz 8GB 2×500GB SATA

SKU CH-PPNR-VS2DQ

1U rack server with a six-core Xeon E5-2603v3 at 1.6GHz, 8GB DDR4, two 500GB 7.2K SATA drives and B140i RAID

  • TypeRack
  • Rack Height1U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon E5 v3
  • MAX Processors2
  • ChipsetIntel C610

Installed Memory Size 8GB

HDD 2 x 500GB

  • Six-core Xeon processor handles multi-threaded workloads at 1.6 GHz
  • 8 GB DDR4 memory supports ECC for data integrity
  • Two 500 GB 7.2 K SATA drives provide 1 TB raw capacity
  • B140i controller enables RAID 0, 1, 5 on SATA drives
  • Redundant hot-swap 550 W power supply keeps the server running

ProLiant DL160 Gen9 1U Server

The HP ProLiant DL160 Gen9 is a 1U rack server designed for general-purpose workloads. It ships with a single Intel Xeon E5-2603v3 six-core processor at 1.6GHz and 8GB of DDR4 ECC registered memory. Two 500GB 2.5-inch SATA hard drives are installed in an eight-bay SFF chassis. A 550W redundant hot-swap power supply is included.

Suits single-CPU starts.

This configuration suits buyers who need a compact 1U platform with room to add a second processor and up to 16 DIMM slots. The B140i software RAID controller supports SATA drives at RAID 0, 1, or 5. Builders who require hardware RAID for SAS drives, a dedicated GPU, or a pre-installed operating system should look at other configurations.

B140i software RAID limits drive choice to SATA

The installed B140i controller provides RAID 0, 1, and 5 for SATA devices only. SAS drives and hardware RAID features are not supported on this controller. If the deployment requires SAS connectivity or battery-backed cache, a compatible hardware RAID card must be sourced separately.

Helstu kostir

  • Six-core Xeon processor handles multi-threaded workloads at 1.6 GHz
  • 8 GB DDR4 memory supports ECC for data integrity
  • Two 500 GB 7.2 K SATA drives provide 1 TB raw capacity
  • B140i controller enables RAID 0, 1, 5 on SATA drives
  • Redundant hot-swap 550 W power supply keeps the server running

Tæknilýsing

BrandHP
SeriesProLiant
ModelProliant DL160 G9
TypeRack
Rack Height1U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon E5 v3
MAX Processors2
ChipsetIntel C610
Installed Memory Size8GB
Memory TypeDDR4
Max Memory Capacity8GB
Memory Features16 DIMM slots, 8 per processor. (4GB/8GB/16GB/32GB/64GB DDR4 up to 2400MT/s ECC Registered, actual memory speed dependent on the processor capability).
Number of Memory Slots16
Storage ControllerB140i Software RAID
HDD InterfaceSATA
SSD (Installed)No
Raid Level0,1,5
Media DrivesNone
GPU TypeMatrox G200
Video Memory16MB
Remote ManagementiLO Management (standard).
LAN Ports2 x Ports
Expansion SlotsCPU1 PCIe Riser 1: 2 PCIe 3.0 Slots (1 & 2) available: 1x Full-Height Half Length, 1x Low Profile slot. Optional kit available to install Flexible LOM in slot 1. CPU 2 Riser (Optional): PCIe 3.0 slot 3 - Full-Height Half Height (Secondary PCIe Riser and dual CPU required).
Operating SystemNo
Compatible/Certified OSMicrosoft Windows Small Business Server 2011/2008, Microsoft Windows Server 2008 R2 SP1/SP2, Microsoft Windows HPC Server 2008 R2, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, Oracle Solaris
Weight63.0000LBS

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

How many 2.5-inch drive bays does the 1U chassis provide?

The chassis has 8 SFF bays for 2.5-inch drives; two are filled with the included 500 GB SATA drives and the remaining six are open for expansion.

What is the correct order for installing the second processor and its memory?

Install the second Xeon processor first, then populate its eight dedicated DIMM slots with registered ECC DDR4 modules; the system will not recognise memory in those slots until the processor is seated.

When should the 550 W hot-swap power supply be replaced?

Replace the 550 W unit if the iLO health LED shows a power-supply fault, if the server logs report a fan or voltage anomaly, or if a second supply is added for redundancy and one module fails.

Einnig í þessum vöruflokki

Fólk bar þetta saman

Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.