Adamant Custom Business Desktop Ryzen 7 9800X3D 128GB 8TB NVMe 10TB HDD RTX PRO 5000 Blackwell
- 2026
- Business Desktops &…
Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.
HPE
A 2U rack array with 12 x 7.68TB SAS SSDs, dual 10/25GbE iSCSI controllers and redundant 580W power supplies
The HPE MSA 2070 SFF ships with twelve 7.68 TB SAS solid-state drives installed in a 2U rack chassis. It is aimed at organisations that need a ready-to-run block storage platform for mixed workloads such as virtualisation, databases and file services.
Two hot-plug 580 W power supplies share the load so a single failure does not interrupt operation. The pair of 10/25 GbE iSCSI four-port controllers provide up to four 10 Gb iSCSI connections for host access while keeping power draw predictable in a standard rack environment.
The enclosure occupies two rack units and uses the installed SAS drives as the primary pool. Additional drive enclosures can be attached to grow raw capacity toward 1.84 PB, letting the same controllers manage a larger dataset without a controller upgrade.
| Brand | HPE |
|---|---|
| Series | MSA 2070 SFF |
| Model | P84183-B25 |
| Workload | General Purpose Server |
| Type | Rack |
| Rack Height | 2U |
| Storage Controller | 2 x 10/25GbE iSCSI 4-port Controllers |
| SSD (Installed) | 12 x 7.68TB SAS SSD |
| Max HDD Capacity | Up to 1.84 PB with maximum capacity expansion |
| Ethernet Controller | 4 x 10Gb iSCSI |
| Compatible/Certified OS | Windows Server; VMware vSphere; Red Hat Linux; SUSE SLES |
| Power Characteristics | 2 x 580W redundant power supplies |
| Sendingarþyngd | 18.14 kg |
| Stærð sendingar | 483 × 457 × 127 mm |
Mount the 2U chassis using the supplied rail kit, connect the two 10/25GbE iSCSI 4-port controllers to your network, then power on both 580W redundant supplies; the step often missed is cabling both controllers for full path redundancy.
The SAS SSDs are sealed with no user-serviceable parts; plan to replace a drive only if the array reports a media error, using a compatible 7.68TB SAS SSD and the hot-swap carrier.
The 4 x 10Gb iSCSI ports saturate before the 12 SAS SSDs or the dual 580W supplies, so sustained throughput tops out at the network link speed.
Einnig í þessum vöruflokki
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Það sem þú greiðir í, og það sem þú sérð verð í.
Sent úr veskinu þínu í greiðsluferlinu
Aðeins til skýringar — verð í vörulistanum eru í Bandaríkjadölum
Enginn gjaldmiðill passar við það.
Veldu tungumálið sem síðan talar við þig á.
Fyrsta heimsókn?
Áttu þegar aðgang?
Það er engin sjálfvirk endurstilling: þessi verslun sendir engan tölvupóst, svo það er enginn einnota tengill til að biðja um. Skildu netfangið eftir á aðganginum og einhver sinnir því handvirkt.
Beiðni skráð
Ekkert er á leiðinni í pósthólfið þitt — þessi verslun sendir engan tölvupóst. Einhver sinnir þessu handvirkt.
Mundir þú það?