Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

Lenovo

Lenovo DPI 100-127V PDU Fixed 1U 1524W

SKU CH-SC2H-RV7C5

A 1U rack-mount power distribution unit delivering 1524 W from a 100–127 V AC input through six NEMA 5-15R outlets

  • TypeConsumer Electronics
  • Delivers up to 1524 W of reliable power to rack equipment
  • Six NEMA 5-15R outlets distribute power to multiple devices from one feed
  • NEMA L5-15P locking plug secures the input connection against accidental disconnect
  • Slim 1U profile fits horizontal or vertical mounting in standard racks
  • Weighs 10.10 lb for straightforward handling and installation

Rack PDU for 100-127 V environments

This Lenovo power distribution unit fits a single rack unit and accepts a NEMA L5-15P inlet. Six NEMA 5-15R outlets deliver 120 V AC power to servers or networking gear. It is built for horizontal or vertical mounting in standard racks.

Continuous 1524 W limit on a 15 A circuit

The unit operates between 100 V and 127 V AC with a 1524 W maximum rating. That ceiling matches a standard 15 A branch circuit, so total connected load must stay below this figure. No internal metering or switching is included, so external monitoring is required for load awareness.

Steel chassis weighs 10.10 lb

The 1.7" tall, 8.8" wide, 4.5" deep metal body mounts securely in either orientation. Fixed inlet cord means the PDU must sit near a compatible receptacle. Six front-facing outlets keep cables accessible while the rear-mounted plug defines placement flexibility.

Helstu kostir

  • Delivers up to 1524 W of reliable power to rack equipment
  • Six NEMA 5-15R outlets distribute power to multiple devices from one feed
  • NEMA L5-15P locking plug secures the input connection against accidental disconnect
  • Slim 1U profile fits horizontal or vertical mounting in standard racks
  • Weighs 10.10 lb for straightforward handling and installation

Tæknilýsing

BrandLenovo
TypeConsumer Electronics

Spurningar um þessa vöru

Should I pick a 1U or 2U PDU for my rack?

This unit occupies exactly 1U of rack space, so it fits a single rack unit without blocking the one above or below.

What does the 1524 W rating mean when I plug in my servers?

It is the maximum continuous power the strip can deliver at 120 V AC; total connected equipment must stay at or below 1524 W to avoid tripping the internal breaker.

How does the NEMA L5-15P input limit what I can connect?

The locking L5-15P plug caps the feed at 15 A on a 100–127 V circuit, which in turn limits the six 5-15R outlets to a combined 1524 W.

Einnig í þessum vöruflokki

Fólk bar þetta saman

Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.