Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

MINUTEMAN

MINUTEMAN ED2000RTXL2U 2000VA 1800W 120V 2U UPS

SKU CH-AS58-8VWKY MPN ED2000RTXL2U

2U rack, tower or wall-mount UPS delivers 2000VA 1800W on-line double-conversion power with nine outlets and 0.9 power factor

  • International Version120V
  • Input Voltage Range0-160VAC
  • Input Frequency50/60Hz +/- 6Hz Auto-sensing
  • Input ConnectionNEMA 5-20P
  • VA Rating2000VA
  • Watts1800W

Yfirstrikaðar útgáfur eru til, en ekki til hér.

  • True on-line double conversion ensures zero transfer time
  • 9 output power factor delivers 1800W from 2000VA rating
  • 2U rack/tower/wall form factor fits high-density installations
  • LCD display shows real-time status and user-selectable 110V/120V output
  • Three controllable load banks allow managed outlet control

Critical Power Protection

The Minuteman Endeavor ED2000RTXL2U is a 2000VA 1800W true on-line double-conversion UPS delivering 120VAC sinewave output with zero transfer time. It fits a 2U rack, tower or optional wall mount and provides nine outlets including one NEMA L5-20R and eight NEMA 5-15/20R receptacles.

Suitable Environments

This unit suits servers, storage, network gear, telecom, VOIP, security and light industrial loads needing continuous conditioning and generator compatibility. It does not suit installations requiring input or output voltages other than 120V, or loads exceeding 1800W. Extended runtime needs external battery packs which are sold separately.

Decisive Specification

The 0.9 output power factor means 1800W real power is available from the 2000VA rating, so the wattage figure decides whether your connected equipment fits within the unit's capacity.

Helstu kostir

  • True on-line double conversion ensures zero transfer time
  • 9 output power factor delivers 1800W from 2000VA rating
  • 2U rack/tower/wall form factor fits high-density installations
  • LCD display shows real-time status and user-selectable 110V/120V output
  • Three controllable load banks allow managed outlet control

Tæknilýsing

BrandMINUTEMAN
SeriesENDEAVOR
ModelED2000RTXL2U
International Version120V
Input Voltage Range0-160VAC
Input Frequency50/60Hz +/- 6Hz Auto-sensing
Input ConnectionNEMA 5-20P
VA Rating2000VA
Watts1800W
Output Voltage120VAC, User selectable: 110VAC
Output Frequency50/60Hz +/- 0.5Hz unless synchronized to line
Outlets9
Outlet Type8 (5-15/20R) & 1 (L5-20R)
Battery TypeSealed Lead Acid
Battery Run TimeHalf Load: 12 min
Full Load: 4 min
Battery Recharge Time8 hours to 90% from total discharge
Battery ReplaceableBM0037
ApprovalscTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU)
Surge Energy Rating1000 Joules
TemperatureOperating Temperature: +32 to +104°F (0 to 40°C)
Storage Temperature: +5 to +113°F (-15 to +45°C)
Humidity95% non-condensing
Dimensions3.5" x 19" x 17"
Weight47.6 lbs.
Sendingarþyngd24.95 kg
Stærð sendingar610 × 559 × 229 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

What input plug must the site already provide for the NEMA 5-20P connection?

The UPS requires a NEMA 5-20P receptacle on a 120 V circuit rated for at least 20 A.

Will the NEMA L5-20R outlet power legacy gear that only has a 5-15 plug?

No, the L5-20R locking outlet accepts only NEMA L5-20P plugs; use the eight 5-15/20R outlets for standard 5-15 or 5-20 plugs.

How can I confirm the unit is delivering true on-line double-conversion output after installation?

The front LCD shows output voltage at 120 V (or 110 V if selected), frequency locked to 50/60 Hz ±0.5 Hz, and the battery status indicates normal charging.

Einnig í þessum vöruflokki

Fólk bar þetta saman

Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.