Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

MINUTEMAN

MINUTEMAN EXR2000RT2UNC UPS 2000VA 1800W 2U Rack/Tower 9 Outlets

SKU CH-PWZP-WHXVJ MPN EXR2000RT2UNC

A line-interactive UPS delivering 2000 VA and 1800 W from a 2U rack or tower chassis with nine outlets and an SNMP card

  • International Version120V
  • Input Voltage Range80 to 164VAC (150 - 271VAC)
  • Input Frequency50/60 Hz, +/- 6 Hz auto-sensing
  • Input ConnectionNEMA 5-20P
  • VA Rating2000 VA
  • Watts1800 W

Yfirstrikaðar útgáfur eru til, en ekki til hér.

  • 1800 W output powers critical servers and network gear
  • 2000 VA capacity handles heavy rackmount workloads
  • 9 outlets including NEMA L5-20R connect diverse equipment
  • 13 minutes at half load keeps systems running during outages
  • 2U rack or tower form fits standard cabinets and desks

2U rack/tower UPS with extended runtime card

The MINUTEMAN EXR2000RT2UNC is a line-interactive uninterruptible power supply rated at 2000 VA and 1800 W. It delivers 120 V output through nine outlets and includes an SNMP-NV6 network card for remote management. The unit fits a 2U rack space or stands as a tower for flexible deployment.

Verify 120 V input and NEMA 5-20P receptacle

Confirm your facility provides 120 V service within the 80 to 164 VAC input window and that a NEMA 5-20P plug can be connected. The UPS requires a 20 A branch circuit and operates at 50 or 60 Hz with ±6 Hz auto-sensing. Rack ears are included for 2U mounting; ensure the rack depth accommodates the 18.96 inch chassis.

Replaces smaller VA units lacking network management

This model steps up from lower-capacity UPS units that cannot sustain 1800 W or lack the SNMP-NV6 card for infrastructure monitoring. The jump is worthwhile when connected loads approach 1800 W or when centralized alerts and graceful shutdown across the network become necessary. Buyers needing only basic desktop backup without remote oversight may find a smaller unit sufficient.

Helstu kostir

  • 1800 W output powers critical servers and network gear
  • 2000 VA capacity handles heavy rackmount workloads
  • 9 outlets including NEMA L5-20R connect diverse equipment
  • 13 minutes at half load keeps systems running during outages
  • 2U rack or tower form fits standard cabinets and desks

Tæknilýsing

BrandMINUTEMAN
SeriesEXR SERIES
ModelEXR2000RT2UNC
International Version120V
Input Voltage Range80 to 164VAC (150 - 271VAC)
Input Frequency50/60 Hz, +/- 6 Hz auto-sensing
Input ConnectionNEMA 5-20P
VA Rating2000 VA
Watts1800 W
Output Voltage120VAC: 101 - 136VAC (208VAC: 186 - 236VAC)
Outlets9
Outlet Type8 (NEMA 5-15/20R) & 1 (NEMA L5-20R)
Battery Run TimeHalf Load: 13 Minute
Full Load: 4.5 Minute
Battery ReplaceableBM0088
Interface PortDB-9, USB, RJ-45
Rackmountable2U
Surge Energy Rating1,000 Joules (800 Joules)
Surge Protection1Gbit RJ45 Ethernet (in/out)
TemperatureOperating 0 to 40°C (+32 to +104°F)
Humidity0 - 95% Non-Condensing
Dimensions3.48" x 23.62" x 18.96"
Weight71.9 lbs.
Sendingarþyngd32.66 kg
Stærð sendingar599 × 483 × 89 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

What comes in the box with the EXR2000RT2UNC and what must I purchase separately?

The UPS ships with DB-9, USB and RJ-45 interface cables, rack-mount brackets and a NEMA 5-20P input cord. Replacement battery cartridges (BM0088) and any NEMA 5-15/20R or L5-20R output cables are sold separately.

Which capacity version should I choose for a 120 V environment?

Only the 120 V international version is listed, rated at 2000 VA and 1800 W with eight NEMA 5-15/20R outlets and one NEMA L5-20R outlet.

How long will the 1800 W rating keep my equipment running during an outage?

At full 1800 W load the internal battery provides 4.5 minutes of runtime; at half load it extends to 13 minutes.

Einnig í þessum vöruflokki

Fólk bar þetta saman

Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.