Vertiv PD5006 server power supply 4 L6-20R L14-30P
A maintenance-bypass POD with four L6-20R outputs and an L14-30P input for GXT5 5-10 kVA UPS units
- Built-in maintenance bypass keeps critical loads powered during UPS servicing
- Four NEMA L6-20R outputs distribute power to multiple rack devices
- Single NEMA L14-30P input simplifies upstream connection
- Automatic transfer to utility protects equipment if the UPS fails
- Plug-and-play replacement for the GXT5 rear POD box
Vertiv Liebert POD PD5 Maintenance Bypass Unit
The Vertiv Liebert PD5-006 is a power output distribution unit with an integrated maintenance bypass. It is designed for GXT5 5-10kVA UPS systems to allow UPS servicing without interrupting power to connected critical loads. The unit automatically transfers the load to utility power during UPS failure events. It replaces the existing POD box on the rear of compatible UPS models.
Four NEMA L6-20R Output Receptacles
This POD provides four NEMA L6-20R output connectors for distributing power to server equipment. A single NEMA L14-30P input connector links the unit to the utility power source. The specific receptacle and plug configuration determines compatibility with your facility wiring and the UPS frame. Verify that your infrastructure matches these exact NEMA ratings before purchasing.
Plug-and-Play Replacement for Rear UPS POD Box
Installation is a plug-and-play process; the unit replaces the existing POD box on the back of the GXT5 UPS. No internal wiring or complex configuration is required for the physical swap. Ensure the UPS model is a supported GXT5 5-10kVA unit, as the PD5-006 will not fit or function on other UPS series or kVA ratings. Incorrect model matching is the primary cause of installation failure.
Helstu kostir
- Built-in maintenance bypass keeps critical loads powered during UPS servicing
- Four NEMA L6-20R outputs distribute power to multiple rack devices
- Single NEMA L14-30P input simplifies upstream connection
- Automatic transfer to utility protects equipment if the UPS fails
- Plug-and-play replacement for the GXT5 rear POD box
Tæknilýsing
Engin birt tæknilýsing fyrir þessa vöru enn.
Spurningar um þessa vöru
What does the 30 A input rating mean for the circuit feeding this unit?
The L14-30P plug requires a 30 A branch circuit; the upstream breaker and wiring must match that rating to avoid nuisance tripping.
How does the L14-30P connector limit the power source I can use?
The L14-30P inlet mates only with a matching NEMA L14-30 receptacle, so the UPS or wall outlet must provide that specific locking configuration.
What rack space or mounting hardware does the PD5006 need?
The unit replaces the existing POD box on the rear of a compatible GXT5 5-10kVA UPS, requiring no additional rack units or separate brackets.