MINUTEMAN ED1000RTXL2UNC 1000VA 900W 2U UPS
Rack-mountable 2U on-line UPS delivers 1000VA/900W with eight NEMA 5-15R outlets and three-minute full-load runtime
- International Version120V
- Input Voltage Range0-160VAC
- Input Frequency50/60Hz +/- 6Hz Auto-sensing
- Input ConnectionNEMA 5-15P
- VA Rating1000VA
- Watts900W
Model ED1000RTXL2UNC
- ED1000RTXL2UNC
- ED1000RTXL2U
- ED10KRT
- ED10KRT-10KTF2
- ED10KRT-3KTF
- ED10KRT-5KTF
- ED10KRT-6KTF2
- ED10KRT-8KTF2
- ED10KTF
- ED2000RTXL2U
- ED2000RTXL2UNC
- ED3000RTXL2U
Rodyti 16 daugiau konfigūracijų
- ED3000RTXL2UNC
- ED-3KTF
- ED5KRT
- ED5KRT-3KTF
- ED5KRT-5KTF
- ED-5KTF
- ED6KRT
- ED6KRT-3KTF
- ED6KRT-5KTF
- ED6KRT-6KTF2
- ED6KTF
- ED8KRT
- ED8KRT-3KTF
- ED8KRT-5KTF
- ED8KRT-6KTF2
- ED8KRT-8KTF2
Perbrauktos versijos egzistuoja, bet šiame sandėlyje jų nėra.
- True on-line double conversion delivers clean 120 V output
- 9 power factor provides 900 W from 1000 VA rating
- 2U rack height fits high-density server cabinets
- Eight NEMA 5-15R outlets with three load banks
- LCD display shows status at a glance
True On-Line Double-Conversion UPS
The Minuteman Endeavor ED1000RTXL2UNC is a 1000VA 900W on-line double-conversion UPS designed for servers and network equipment that require continuous power conditioning. It supplies 120VAC output with a user-selectable 110VAC option and a 0.9 output power factor. The unit operates from a 120VAC input with a 0-160VAC range and auto-sensing 50/60Hz frequency.
Rack Tower Wall Mount 2U Form Factor
This 2U high unit fits standard 19-inch racks and includes attached rackmount ears for immediate installation. It can also be used as a tower or wall-mounted with an optional kit. Eight NEMA 5-15R receptacles are arranged in three controllable load banks. The input connects via a NEMA 5-15P plug. An LCD display provides status information.
Sealed Lead Acid Battery 3 Minute Full Load Runtime
The sealed lead acid battery delivers 3 minutes of runtime at full 900W load and 11 minutes at half load. Recharge to 90 percent capacity takes 8 hours from total discharge. The battery is user-replaceable using the BM0035 module. Surge protection is rated at 1000 joules. Operating temperature spans 32 to 104°F with 95 percent non-condensing humidity tolerance. Approvals include cTUVus UL1778, FCC Class B, CE, Energy Star and RoHS2.
Privalumai
- True on-line double conversion delivers clean 120 V output
- 9 power factor provides 900 W from 1000 VA rating
- 2U rack height fits high-density server cabinets
- Eight NEMA 5-15R outlets with three load banks
- LCD display shows status at a glance
Specifikacijos
| Brand | MINUTEMAN |
|---|---|
| Model | ED1000RTXL2UNC |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/- 6Hz Auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000VA |
| Watts | 900W |
| Output Voltage | 120VAC, User selectable: 110VAC |
| Output Frequency | 50/60Hz +/- 0.5Hz unless synchronized to line |
| Outlets | 8 |
| Outlet Type | (8) NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 11 min Full Load: 3 min |
| Battery Recharge Time | 8 hours to 90% from total discharge |
| Battery Replaceable | BM0035 |
| Approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU) |
| Surge Energy Rating | 1000 Joules |
| Temperature | Operating Temperature: +32 to +104°F (0 to 40°C) Storage Temperature: +5 to +113°F (-15 to +45°C) |
| Humidity | 95% non-condensing |
| Dimensions | 13.3" x 3.5" x 19" |
| Weight | 29.3 lbs. |
| Siuntos svoris | 17.24 kg |
| Pakuotės dydis | 599 × 508 × 224 mm |
Kiti šio modelio variantai
Dar 5 toje pačioje serijoje
Ta pati šeima, bet skiriasi atmintis, aušintuvas ar dažnis — palyginkite prieš apsispręsdami.
MINUTEMAN ED2000RTXL2U 2000VA 1800W 120V 2U UPS
- 120V
- 0-160VAC
MINUTEMAN ED2000RTXL2UNC 2000VA 1800W 2U UPS
- 120V
- 0-160VAC
MINUTEMAN ED3000RTXL2U 3000VA 2700W UPS 2U Tower/Rack/Wall Mountable
- 120V
- 0-160VAC
MINUTEMAN ED3000RTXL2UNC 3000VA 2700W 2U UPS
- 120V
- 0-160VAC
Klausimai apie šią prekę
What is the battery run time at full 900 W load?
The UPS provides 3 minutes of runtime when the connected equipment draws the full 900 W.
What are the operating temperature limits for continuous use?
The unit is rated for continuous operation from 0 to 40 °C (32 to 104 °F) with up to 95 % non-condensing humidity.
Which input plug and circuit are required to power this UPS?
It connects via a NEMA 5-15P plug and requires a 120 V AC circuit capable of supplying the 1000 VA rating.
Taip pat šiame skyriuje
Kiti pirkėjai taip pat lygino
Ta pati lentyna, tas pats atsiskaitymas — aštuonios monetos ir 30 minučių fiksuotas kursas.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case