APC AP7516 Basic PDU 208V 3PH 50A 6×C19 1U
Distributes 208 V three-phase power at up to 14.4 kW through six C19 outlets in a 1U horizontal rackmount with a CS8365 input plug
- TypeBasic
- Rack Size1U
- StyleRack
- CertificationscUL Listed,CSA C22.2 No. 60950-1-03,METI Denan,UL 60950-1,UL
- ROHSRoHS 7b Exemption
- Input Voltage208V 3PH
- Delivers 14.4 kW three-phase power to high-density racks
- Six IEC C19 outlets connect multiple servers from one branch whip
- 1U horizontal form factor preserves rack space for equipment
- 8 ft CS8365 input cord reaches overhead or floor power sources
- cUL, CSA, METI and UL 60950-1 certifications confirm safety compliance
Three-Phase Rack PDU
The APC AP7516 is a new basic power distribution unit designed for 208V three-phase environments. It mounts in a single 1U horizontal rack space and supplies up to 14.4kW through six IEC 320 C19 outlets. Data-centre operators and network engineers use it to feed multiple servers or switches from one branch circuit.
Six C19 Outlets and CS8365 Input
The unit ships with an 7.8 ft cord terminated in a CS8365 connector, delivering 50A per phase with a regulatory derated limit of 40A. Six C19 receptacles let you connect equipment with matching IEC 320 C19 plugs directly, reducing the need for adapter cables inside the rack.
Check Phase Voltage and Connector Compatibility
Verify that your facility provides 208V three-phase power at 50/60 Hz and that the CS8365 inlet matches your branch whip. Confirm each connected device accepts 200V or 208V output and uses a C19 plug. The operating range spans 23 to 113 °F with 5 to 95 % relative humidity.
Ciri-ciri utama
- Delivers 14.4 kW three-phase power to high-density racks
- Six IEC C19 outlets connect multiple servers from one branch whip
- 1U horizontal form factor preserves rack space for equipment
- 8 ft CS8365 input cord reaches overhead or floor power sources
- cUL, CSA, METI and UL 60950-1 certifications confirm safety compliance
Spesifikasi
| Brand | APC |
|---|---|
| Model | AP7516 |
| Type | Basic |
| Rack Size | 1U |
| Style | Rack |
| Certifications | cUL Listed,CSA C22.2 No. 60950-1-03,METI Denan,UL 60950-1,UL Listed |
| ROHS | RoHS 7b Exemption |
| Input Voltage | 208V 3PH |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 50A per phase |
| Regulatory Derated Input Current | 40A |
| Input Connector(s) | CS8365 |
| Cord Length | 8 ft |
| Output Voltage | 200V, 208V |
| Output Watts (VA) | 14.4kW |
| Output Connector(s) | (6) IEC 320 C19 |
| Overload Protection | 40A |
| Operating Environment | 23 - 113 °F (-5 - 45 °C) |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0-10000 feet (0-3000 meters) |
| Storage Temperature | -13 - 149 °F (-25 - 65 °C) |
| Storage Relative Humidity | 5 - 95% |
| Storage Elevation | 0-50000 feet (0-15000 meters) |
| Features | Resettable circuit breakers - Enables a quick recovery from overload events. Horizontal mounting capability High Power Density Rack-Mountable - Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment. Single input power source - Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. Wide range of input and output connections - Product family includes a variety of in |
| Dimensions | 17.2" x 10" x 1.72" |
| Weight | 17.56 lbs. |
| Berat penghantaran | 10.89 kg |
| Dimensi bungkusan | 559 × 502 × 241 mm |
Soalan tentang produk ini
What maintenance or replacement will the AP7516 need later?
The unit has no user-serviceable parts and no internal batteries; the only items that may require attention are the six IEC 320 C19 outlets and the CS8365 input cord if physical damage occurs.
What limit appears first when the AP7516 runs continuously at full load?
The regulatory derated input current of 40 A per phase and the 40 A overload protection will trip before the 50 A plug rating is reached, capping usable power at the 14.4 kW nameplate.
How much noise and heat does the AP7516 produce when running all day?
As a basic passive PDU it has no fans, so audible noise is negligible; waste heat is limited to connector and cord resistance and the unit is rated for continuous operation up to 45 °C ambient.