Kami menerima kripto — jadi koin yang anda simpan boleh membeli perkakasan sebenar.Bayar dengan kripto, belanjakannya untuk perkakasan sebenar. Penghantaran berinsurans percuma ke seluruh dunia untuk belian melebihi USD 399. Kotak biasa tanpa jenama, dihantar dari Jerman.Penghantaran berinsurans percuma untuk belian melebihi USD 399. Kadar anda dikunci selama 30 minit sebaik sahaja proses pesanan bermula.Kadar dikunci selama 30 minit. Setiap item disegel, nombor sirinya disemak, dan dilindungi waranti 24 bulan.Disegel, waranti 24 bulan.

Barang disimpan Log masuk

CyberPower

CyberPower AVRG900U 900 VA 480 W 12 Outlets UPS

SKU CH-DR78-GWGZ4 MPN AVRG900U

Provides battery backup and automatic voltage regulation for desktop systems with twelve NEMA 5-15R outlets and USB management

  • International Version120V
  • Input Voltage Range90V ac - 148V ac
  • Input Frequency60 Hz +/- 3 Hz
  • Input ConnectionNEMA 5-15P
  • VA Rating900 VA
  • Watts480 Watts

VA 900 VA

  • 900 VA / 480 W capacity keeps desktop gear running during outages
  • Automatic Voltage Regulation corrects brownouts and over-voltages without draining the battery
  • 12 NEMA 5-15R outlets plus USB and RJ11 ports protect power and data lines
  • Simulated sine wave output delivers cost-effective backup for equipment that does not need pure sine wave
  • GreenPower UPS bypass technology reduces energy consumption when utility power is normal

Battery backup for desktop and networking gear

The CyberPower AVRG900U is a line-interactive UPS rated at 900 VA and 480 W with 12 NEMA 5-15R outlets. It supplies simulated sine wave power and includes Automatic Voltage Regulation to correct fluctuations without using the battery. A USB port and RJ11 protection add connectivity for management and phone-line surge safety.

Suits home offices needing many protected outlets

This unit fits setups that require a single UPS for a computer, monitor, router and peripherals. It is not for equipment that demands pure sine wave output or for loads exceeding 480 W. Buyers who need extended runtime at full load should look at larger-capacity models.

900 VA / 480 W capacity with 12 outlets

The VA and wattage ratings decide whether your combined equipment load stays within limits. At half load the battery lasts 10 minutes; at full load it lasts 2 minutes. Recharge takes 8 hours and the replaceable battery uses the RB1290A pack.

Ciri-ciri utama

  • 900 VA / 480 W capacity keeps desktop gear running during outages
  • Automatic Voltage Regulation corrects brownouts and over-voltages without draining the battery
  • 12 NEMA 5-15R outlets plus USB and RJ11 ports protect power and data lines
  • Simulated sine wave output delivers cost-effective backup for equipment that does not need pure sine wave
  • GreenPower UPS bypass technology reduces energy consumption when utility power is normal

Spesifikasi

BrandCyberPower
SeriesAVR Series
ModelAVRG900U
International Version120V
Input Voltage Range90V ac - 148V ac
Input Frequency60 Hz +/- 3 Hz
Input ConnectionNEMA 5-15P
VA Rating900 VA
Watts480 Watts
Output Voltage120Vac +/- 5%
Output Frequency60 Hz +/- 1%
Outlets12
Outlet TypeNEMA 5-15R
Battery TypeSealed Lead Acid
Battery Run TimeHalf Load: 10 minutes
Full Load: 2 minutes
Battery Recharge Time8 Hour(s)
Battery ReplaceableRB1290A
AlarmsOn Battery, Low Battery, Overload, Fault
Interface PortUSB
Management SoftwarePowerPanel Personal Edition
ApprovalsUL1778 4th, cUL 107.3-05, FCC/DoC Class B, RoHS
Surge Energy Rating1030 Joules
ProtectionInternal circuitry limiting / circuit breaker
Features900 VA / 480 Watts Simulated Sine Wave UPS
Line-Interactive Topology
Automatic Voltage Regulation (AVR)
GreenPower UPS Bypass Technology
ENERGY STAR Qualified
Full-time Surge Protection and Battery Backup
Desktop Form Factor
12 Outlets / USB Port / RJ11 Protection
EMI/RFI Filters
PowerPanel Personal Edition
Dimensions3.50" x 12.20" x 7.00"
Weight14.20 lbs.
VA900 VA
WattN/A
OptionsNo
Berat penghantaran7.26 kg
Dimensi bungkusan373 × 246 × 130 mm

Versi lain model ini

1 lagi dalam julat yang sama

Keluarga yang sama, memori, penyejuk atau kelajuan jam yang berbeza — bandingkan sebelum membuat keputusan.

Soalan tentang produk ini

When will the RB1290A battery need replacing?

The sealed lead‑acid battery is user‑replaceable with the RB1290A cartridge; typical service life is three to five years depending on discharge cycles and ambient temperature.

What stops the UPS from running longer at full load?

At the full 480 W rating the internal battery provides only 2 minutes of runtime before the low‑battery alarm sounds and the unit shuts down.

How much heat and noise should I expect when the AVRG900U runs continuously?

The line‑interactive design with AVR and GreenPower bypass keeps fan activity low during normal operation; only during battery or overload events does the audible alarm and cooling fan become noticeable.