Kami menerima kripto — jadi koin yang anda simpan boleh membeli perkakasan sebenar.Bayar dengan kripto, belanjakannya untuk perkakasan sebenar. Penghantaran berinsurans percuma ke seluruh dunia untuk belian melebihi USD 399. Kotak biasa tanpa jenama, dihantar dari Jerman.Penghantaran berinsurans percuma untuk belian melebihi USD 399. Kadar anda dikunci selama 30 minit sebaik sahaja proses pesanan bermula.Kadar dikunci selama 30 minit. Setiap item disegel, nombor sirinya disemak, dan dilindungi waranti 24 bulan.Disegel, waranti 24 bulan.

Barang disimpan Log masuk

DELL

DELL LSI SAS 2008 8 Port Controller Daughter Card 471NY

SKU CH-ZX18-KTA4B

Adds eight internal SAS or SATA ports at 6Gb/s via two SFF-8087 connectors for Dell PowerEdge 12G and 13G servers

  • Compatible ManufacturerFor Dell
  • Compatible ModelsFor Dell PowerEdge R720, R720xd, R820, T620, R920, and other
  • Dimensions(L × W × H): 4.5 × 2.5 × 0.5 inches
  • Weight0.25 lbs
  • 8 internal drives via two SFF-8087 mini-SAS connectors
  • 6Gb/s transfer speeds for SAS 2.0 and SATA III devices
  • Direct compatibility with PowerEdge 12G/13G servers (no bracket required)
  • Hardware-assisted RAID 0, 1, 1E, and JBOD configurations
  • PCIe 2.0 x8 interface for optimized performance

Dell LSI SAS 2008 Daughter Card

The Dell LSI SAS 2008 8-port controller daughter card (part 471NY) adds eight internal SAS or SATA drive connections to compatible PowerEdge servers. It uses an LSI SAS 2008 chip and two SFF-8087 mini-SAS ports to deliver 6Gb/s transfer speeds.

Fits 12th- and 13th-gen Dell PowerEdge servers

This card installs directly into Dell PowerEdge R720, R720xd, R820, T620, R920 and similar 12th- or 13th-generation chassis without extra brackets. It is not for systems lacking the proprietary daughter-card slot or for users needing more than eight internal ports.

PCIe 2.0 x8 host interface

The board connects through a PCIe 2.0 x8 link, which sets the maximum throughput ceiling for all attached drives. Verify that the target server provides this exact slot type before purchase.

Ciri-ciri utama

  • 8 internal drives via two SFF-8087 mini-SAS connectors
  • 6Gb/s transfer speeds for SAS 2.0 and SATA III devices
  • Direct compatibility with PowerEdge 12G/13G servers (no bracket required)
  • Hardware-assisted RAID 0, 1, 1E, and JBOD configurations
  • PCIe 2.0 x8 interface for optimized performance

Spesifikasi

BrandDell
Part Number471NY
Compatible ManufacturerFor Dell
Compatible ModelsFor Dell PowerEdge R720, R720xd, R820, T620, R920, and other 12th/13th-gen Dell servers
Dimensions(L × W × H): 4.5 × 2.5 × 0.5 inches
Weight0.25 lbs

Soalan tentang produk ini

How many internal drives can the 8-port LSI SAS 2008 controller support before hitting the connector limit?

The card provides two SFF-8087 mini-SAS connectors, each carrying four lanes, so up to eight SAS or SATA drives can be attached directly.

What thermal or power headroom should I expect when the daughter card runs continuously in a PowerEdge chassis?

The low-profile daughter card draws power from the server's dedicated slot and relies on the system fans; no separate cooling or external power cable is required.

Which server-side slot must be free on my R720 or R720xd for this 471NY card to install?

It plugs into the internal SAS daughter-card connector on the motherboard of compatible 12th- and 13th-generation PowerEdge servers.

Juga di rak ini

Pelanggan turut membandingkan

Rak yang sama, checkout yang sama — lapan koin kripto dan kunci kadar 30 minit.