myVolts
myVolts STP6005D 3 LED adjustable power supply 0-60V 0-5A
Adjustable DC supply delivering 0-60 V at up to 5 A with dual readouts, CV/CC auto-switching, 80 % efficiency and short-circuit, over-temperature and current-limit protection
- TypeAT
- Adjustable 0-60V output covers wide test scenarios
- Constant voltage and current modes switch automatically
- Dual display shows voltage and current simultaneously
- Built-in short-circuit and over-temperature protection
- Up to 80% efficiency reduces wasted heat
Lab bench power supply
The myVolts STP6005D is a bench-top unit that delivers continuously adjustable DC output from 0 to 60V and 0 to 5A. It operates in constant voltage or constant current mode with automatic crossover and is intended for factory maintenance, calibration work or integration into test equipment cabinets. Dual three-digit LED displays show voltage and current independently.
Protection and efficiency features
The supply includes current-limiting buck operation, short-circuit protection and over-temperature protection to safeguard both the unit and the device under test. Regulation rates are 0.5% + 3mV for voltage and 0.2% + 3mA for current, with ripple and noise specified at 50mVrms and 50mArms respectively. Overall power efficiency reaches 80%.
0-60V 0-5A adjustable range
The single specification that decides suitability is the continuous 0 to 60 volt and 0 to 5 amp output envelope. Any application needing more than 5 amps or more than 60 volts cannot use this unit. The AC input fuse is rated F5AL at 250VAC and the operating temperature range is 0 to 40°C.
Ciri-ciri utama
- Adjustable 0-60V output covers wide test scenarios
- Constant voltage and current modes switch automatically
- Dual display shows voltage and current simultaneously
- Built-in short-circuit and over-temperature protection
- Up to 80% efficiency reduces wasted heat
Spesifikasi
| Type | AT |
|---|
Soalan tentang produk ini
What is the fuse rating I may need to replace on the STP6005D?
The unit uses a F5AL 250VAC fuse that can be replaced if it blows.
What limits continuous operation before protection activates?
Over-temperature protection engages when the internal temperature rises beyond safe limits during sustained loads.
How much ripple and noise appear on the output at full load?
Output ripple and noise are specified as 50mVrms for voltage and 50mArms for current across the 5Hz to 1MHz range.