CyberPower
CyberPower OL1KRTHD UPS 1000VA 1000W 100-125V 2U 8 Outlets Sine Wave
Double-conversion online UPS delivers 1000 VA/1000 W pure sine-wave power with user-configurable output voltage, eight NEMA 5-15R outlets, and 12-minute half-load runtime in a 2U rack/tower chassis
- International Version120V
- Input Voltage Range100 - 125V
- Input Frequency40 - 70 Hz
- Input ConnectionNEMA 5-15P
- VA Rating1000 VA
- Watts1000 Watts
- Delivers 1000 W continuous power with unity power factor
- Double-conversion topology supplies pure sine wave output for sensitive equipment
- Configurable output voltage from 100 to 125 VAC matches regional requirements
- Eight NEMA 5-15R outlets and 710 J surge protection in a 2U rackmount frame
- User-replaceable sealed lead-acid battery recharges to 90 % in 4 hours
Capacity and Topology
The CyberPower OL1KRTHD is a double-conversion online UPS rated at 1000 VA and 1000 W with a unity power factor. It accepts 100–125 V input through a NEMA 5-15P plug and delivers configurable sine-wave output at 100, 110, 115, 120 or 125 VAC. The unit fits in a 2U rack or tower form factor and provides eight NEMA 5-15R outlets.
Who It Suits and Who It Does Not
This UPS suits installations that require continuous sine-wave power with zero transfer time for sensitive electronics. It is not suited for environments that need extended runtime at full load because the battery delivers only 3.8 minutes at 1000 W. Buyers who need longer backup duration or higher VA capacity should consider other models.
Deciding Specification
The double-conversion topology with unity power factor means the full 1000 W is available as real power without derating. If your connected load approaches 1000 W and requires pure sine-wave output with no break on mains failure, this specification confirms the unit will meet that requirement.
Öne çıkanlar
- Delivers 1000 W continuous power with unity power factor
- Double-conversion topology supplies pure sine wave output for sensitive equipment
- Configurable output voltage from 100 to 125 VAC matches regional requirements
- Eight NEMA 5-15R outlets and 710 J surge protection in a 2U rackmount frame
- User-replaceable sealed lead-acid battery recharges to 90 % in 4 hours
Teknik özellikler
| Brand | CyberPower |
|---|---|
| Model | OL1KRTHD |
| International Version | 120V |
| Input Voltage Range | 100 - 125V |
| Input Frequency | 40 - 70 Hz |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000 VA |
| Watts | 1000 Watts |
| Output Voltage | 100/110/115/120/125 VAC +/- 2% (configurable) |
| Outlets | 8 |
| Outlet Type | 8 x NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | 12 minutes / 3.8 minutes Runtime (half/full) |
| Battery Recharge Time | 4 Hours (0% to 90% charged) |
| Battery Replaceable | Yes |
| Alarms | Battery Mode Low Battery Overload UPS Fault |
| Interface Port | Serial |
| Approvals | UL1778 CSA C22.2 No.107.3 FCC Part 15 Class B |
| Rackmountable | 2U |
| Surge Energy Rating | 710 Joules |
| Protection | UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection |
| Temperature | Operating Temperature: 32 - 104 °F (0 - 40 °C) Storage Temperature: 5 - 113 °F (-15 - 45 °C) |
| Humidity | Operating Relative Humidity: 0 - 90 % (non-condensing) Storage Relative Humidity: 0 - 95% (non-condensing) |
| Dimensions | 3.4" x 17.05" x 11.42" |
| Weight | 28 lbs. |
| Kargo ağırlığı | 16.50 kg |
| Koli boyutu | 560 × 390 × 240 mm |
Bu ürünle ilgili sorular
How do I verify the OL1KRTHD is delivering clean sine-wave power after setup?
Check the LCD for "Online" mode and a stable output voltage reading of 100, 110, 115, 120, or 125 VAC within +/- 2%; the unit alarms on Battery Mode, Low Battery, Overload, or UPS Fault if operation deviates.
What comes in the box and which cables or accessories must I buy separately?
The package includes the 2U UPS with 8 NEMA 5-15R outlets, an attached NEMA 5-15P input cord, and a serial interface cable; rack-mount brackets and any USB or network management cards are sold separately.
Should I choose the 100 V, 110 V, 115 V, 120 V, or 125 V output setting for my equipment?
Match the setting to your devices' nameplate voltage — most North American IT gear uses 120 V; the OL1KRTHD lets you select 100, 110, 115, 120, or 125 VAC via the front panel, each held within +/- 2%.