DELL
DELL PowerEdge R760 2U Rack Server 2x Xeon Gold 5415+ 2.9GHz 1TB DDR5 H965i 4x 960GB SSD 5720 iDRAC9 2x 1400W
A 2U rack server with dual 8-core Xeon Gold 5415+ CPUs, 1 TB DDR5-4800 memory, H965i RAID controller, four 960 GB SATA SSDs, quad-port 1 GbE networking, iDRAC9 Datacenter management.
- TypeRack
- Rack Height2U
- Redundant Hot-swap PowerYes
- CPU TypeIntel Xeon
- CPU Speed2.9GHz (4.1GHz Turbo)
- CPU SocketLGA 4677
- Dual Xeon Gold 5415+ 8-core CPUs with 4.1GHz turbo for heavy compute
- 1TB DDR5-4800 ECC registered memory across 32 slots for large datasets
- PERC H965i RAID controller with 8GB NV cache supporting RAID 0/1/5/6/10/50/60
- Four 960GB SATA enterprise SSDs in 16-bay 2.5" chassis for fast storage
- iDRAC9 Datacenter plus quad-port 1GbE OCP 3.0 for remote management
Purpose-built enterprise compute
The Dell PowerEdge R760 is a 2U rack server equipped with dual Intel Xeon Gold 5415+ processors running at 2.9GHz with a 4.1GHz turbo frequency. Each CPU provides eight cores for a total of sixteen cores across two sockets. The system ships with 1TB of DDR5-4800 ECC registered memory populated across thirty-two slots, leaving headroom toward the 8TB maximum capacity. It targets virtualization, AI inference, database and high-performance computing clusters that demand dense, scalable processing.
Thermal and power profile
Dual 1400W platinum-efficiency hot-swap power supplies deliver redundant power to the platform. The 2U chassis uses forced-air cooling designed for the sixteen 2.5-inch drive bays and full processor load. Fan speed scales with inlet temperature and workload intensity, so acoustic output rises under sustained compute or storage I/O. Redundant power and hot-swap capability allow supply replacement without service interruption.
Build and connectivity
The chassis provides sixteen hot-swap 2.5-inch bays supporting SAS, SATA and NVMe devices; four 960GB SATA SSDs are installed. A PERC H965i front RAID controller with 8GB non-volatile cache manages RAID 0, 1, 5, 6, 10, 50 and 60. Networking is handled by a Broadcom 5720 quad-port 1GbE OCP 3.0 adapter. iDRAC9 Datacenter enables full out-of-band remote management. Ready Rails and a front bezel are included for rack mounting.
Öne çıkanlar
- Dual Xeon Gold 5415+ 8-core CPUs with 4.1GHz turbo for heavy compute
- 1TB DDR5-4800 ECC registered memory across 32 slots for large datasets
- PERC H965i RAID controller with 8GB NV cache supporting RAID 0/1/5/6/10/50/60
- Four 960GB SATA enterprise SSDs in 16-bay 2.5" chassis for fast storage
- iDRAC9 Datacenter plus quad-port 1GbE OCP 3.0 for remote management
Teknik özellikler
| Brand | DELL |
|---|---|
| Series | PowerEdge |
| Model | R760 |
| Type | Rack |
| Rack Height | 2U |
| Redundant Hot-swap Power | Yes |
| CPU Type | Intel Xeon |
| CPU Speed | 2.9GHz (4.1GHz Turbo) |
| CPU Socket | LGA 4677 |
| Number of CPU Cores | 8 Core-Processors |
| CPU Features | Gold 5415+ |
| # of Processors Installed | 2 |
| MAX Processors | 2 |
| Installed Memory Size | 1TB |
| Memory Type | DDR5 |
| Max Memory Capacity | 8TB |
| Number of Memory Slots | 32 |
| Hard Drive (Installed) | None |
| Storage Controller | Dell Perc H965i Controller |
| HDD Interface | SATA |
| SSD (Installed) | 4 x 960GB SATA SSD |
| Raid Level | RAID 0/1/5/6/10/50/60 |
| Ethernet Controller | Dell EMC Broadcom 5720 Quad Port 1GbE OCP 3.0 Network Card |
| Remote Management | iDRAC9 Datacenter |
| LAN Ports | 4 x Ports |
| Management Port | RJ 45 |
| Operating System | No |
Bu ürünle ilgili sorular
How do I install the 1TB DDR5-4800 memory kit across the 32 slots in the R760?
Populate all 32 DIMM sockets with the supplied 32 GB modules, matching the per-processor channel layout shown in the system service manual; the common mistake is leaving a channel unbalanced, which forces the memory to run at a lower speed.
When will the 960 GB SATA SSDs or the PERC H965i cache module need replacement?
The SSDs are rated for enterprise write endurance and the H965i includes an 8 GB non-volatile cache; monitor SMART wear indicators and the controller's battery health via iDRAC9, replacing drives once the media-wear metric approaches the vendor threshold.
What thermal or power limit appears first when both Xeon Gold 5415+ CPUs sustain 4.1 GHz turbo under full load?
The dual 1400 W platinum power supplies and the 2U chassis cooling set the practical ceiling; sustained all-core turbo will hit the platform power budget before the processors reach their thermal junction maximum.
Bu reyondan diğerleri
Müşteriler bunları karşılaştırdı
Aynı raf, aynı sipariş tamamlama — sekiz koin ve 30 dakikalık kur kilidi.
Higole 11.6" Touch All-in-One PC Celeron N5095 8GB 128GB
- 11.6"
- 1366 x 768
Toemaagic All-in-One PC 24" FHD i7 4.0GHz 16GB 512GB White
- Toemaagic
- 16 GB
Lenovo A100 23.8" FHD All-in-One PC Intel N100 32GB DDR4 2TB SSD 1TB Dock Windows 11 Pro White
- All-in-One PC
- All-in-One



