DELL
DELL PowerEdge T440 5U Rack Server 2x Xeon Gold 5118 2.3GHz 12 Core 64GB DDR4 H330 4x 960GB SSD
A 5U tower server with dual 12-core Xeon Gold 5118 processors at 2.3 GHz, 64 GB DDR4 memory, PERC H330 controller and four 960 GB SATA SSDs
- TypeRack
- Rack Height5U
- Redundant Hot-swap PowerYes
- CPU TypeIntel Xeon
- CPU Speed2.3GHz (3.2GHz Turbo)
- CPU SocketLGA 3647
- Dual Xeon Gold 5118 CPUs deliver 24 cores at 2.3 GHz base clock
- 64 GB DDR4-2400 ECC memory supports demanding virtualization workloads
- PERC H330 controller manages 4× 960 GB SATA SSDs for fast storage
- 16 hot-swap 2.5″ bays enable scalable capacity without downtime
- Dual 750 W platinum power supplies provide redundant hot-swap reliability
Dual Xeon Gold 5118 server
The Dell PowerEdge T440 is a 5U rack server equipped with two Intel Xeon Gold 5118 processors, each running at 2.3 GHz with a 3.2 GHz turbo frequency. Twelve cores per CPU deliver 24 threads for virtualization, database hosting and business-critical workloads. The system ships with 64 GB of DDR4-2400 ECC registered memory across four modules. Four 960 GB enterprise SATA SSDs are pre-installed behind the Dell PERC H330 storage controller.
Sixteen hot-swap bays and expansion
Sixteen 2.5-inch hot-swap drive bays support SAS, SATA and SSD media, leaving twelve bays free for additional capacity or performance tiers. The PERC H330 controller provides 12 Gb/s SAS/SATA connectivity for the installed drives and any future additions. Integrated dual-port Gigabit Ethernet handles network traffic, while PCI Express slots remain available for RAID, networking, GPU or other add-in cards. iDRAC 9 Express enables remote management and lifecycle control without a dedicated monitor or keyboard.
Redundant 750 W platinum supplies
Two hot-plug 750 watt platinum-efficiency power supplies operate in redundant mode, maintaining uptime if one unit fails. The 5U chassis directs airflow across the dual-socket processor complex and memory DIMMs, keeping thermals stable under sustained multi-threaded loads. Fan speeds scale with inlet temperature, so acoustic output remains appropriate for a data-centre environment rather than an office desktop. Power draw varies with workload but stays within the dual-supply budget.
Öne çıkanlar
- Dual Xeon Gold 5118 CPUs deliver 24 cores at 2.3 GHz base clock
- 64 GB DDR4-2400 ECC memory supports demanding virtualization workloads
- PERC H330 controller manages 4× 960 GB SATA SSDs for fast storage
- 16 hot-swap 2.5″ bays enable scalable capacity without downtime
- Dual 750 W platinum power supplies provide redundant hot-swap reliability
Teknik özellikler
| Brand | DELL |
|---|---|
| Series | PowerEdge |
| Model | T440 |
| Type | Rack |
| Rack Height | 5U |
| Redundant Hot-swap Power | Yes |
| CPU Type | Intel Xeon |
| CPU Speed | 2.3GHz (3.2GHz Turbo) |
| CPU Socket | LGA 3647 |
| Number of CPU Cores | 12 Core-Processors |
| CPU Features | Gold 5118 |
| # of Processors Installed | 2 |
| MAX Processors | 2 |
| Installed Memory Size | 64GB |
| Memory Type | DDR4 |
| Max Memory Capacity | 1TB |
| Number of Memory Slots | 16 |
| Hard Drive (Installed) | None |
| Storage Controller | Dell Perc H330 Controller |
| HDD Interface | SATA |
| SSD (Installed) | 4 x 960GB SATA SSD |
| Raid Level | RAID 0/1/5/10/50 |
| Ethernet Controller | Integrated Dell 2x1GbE Dual Port Ethernet Adapter |
| Remote Management | iDRAC9 Express |
| LAN Ports | 2 x Ports |
| Management Port | RJ 45 |
| Operating System | No |
Bu ürünle ilgili sorular
Will the two Xeon Gold 5118 processors at 2.3 GHz hit a thermal limit before the 750 W power supplies do under sustained load?
Dual 750 W platinum supplies provide headroom well above the processor draw, so the first sustained limit is typically CPU thermal throttling rather than power capacity.
How loud are the fans and how much heat does the 5U chassis produce when the server runs 24/7?
The 5U tower design uses multiple hot-swap fans that ramp with inlet temperature; expect noticeable airflow noise and significant room heat from dual CPUs and four SSDs under continuous operation.
Which rails or rack kit do I need to mount this 5U tower in a standard cabinet?
The front bezel and ready rails are not included; a Dell rack conversion kit for the T440 5U chassis must be purchased separately for rack mounting.
Bu reyondan diğerleri
Müşteriler bunları karşılaştırdı
Aynı raf, aynı sipariş tamamlama — sekiz koin ve 30 dakikalık kur kilidi.
Higole 11.6" Touch All-in-One PC Celeron N5095 8GB 128GB
- 11.6"
- 1366 x 768
Toemaagic All-in-One PC 24" FHD i7 4.0GHz 16GB 512GB White
- Toemaagic
- 16 GB
Lenovo A100 23.8" FHD All-in-One PC Intel N100 32GB DDR4 2TB SSD 1TB Dock Windows 11 Pro White
- All-in-One PC
- All-in-One



