Vertiv
Vertiv GXT5-1500LVRT2UXL UPS 1500VA 1350W 120V 2U
Online double-conversion UPS delivers 1500 VA, 1350 W with 0 ns transfer time and six NEMA 5-15R outlets in a 2U rack/tower
- International Version120V
- Input Voltage Range60-150V
- Input Frequency40-70Hz; Auto Sensing
- Input ConnectionNEMA 5-15P
- VA Rating1500VA
- Watts1350W
- Online double-conversion with zero transfer time protects critical loads
- Energy Star 2.0 certified and up to 98% ECO-mode efficiency cuts energy cost
- 0 output power factor delivers full 1350 W from 1500 VA rating
- Six NEMA 5-15R outlets with individual control enable remote reboot of hung devices
- Compact 2U rack/tower form factor fits dense IT environments
Mission-critical power protection
The Vertiv Liebert GXT5-1500LVRT2UXL is a 1500VA, 1350W online double-conversion UPS designed for mission-critical IT equipment. It delivers continuous power conditioning with a 0 ns transfer time and a unity output power factor of 1.0. Six NEMA 5-15R outlets provide individually controllable power distribution for connected loads.
Sustained load behaviour
At full 1350W load the internal VRLA battery provides 6.7 minutes of runtime, extending to 18.8 minutes at half load. The double-conversion topology maintains a regulated output of 110, 115, 120 or 125VAC within +/-3% regardless of input fluctuations between 60 and 150V. Active ECO mode raises efficiency to 98% when utility power is stable.
Thermals noise and power
The unit operates from 32°F to 104°F in environments up to 95% non-condensing humidity. Energy Star 2.0 certification confirms high efficiency in normal online mode, reducing waste heat during continuous operation. A 10 ft input cord and 2U rack/tower form factor allow flexible placement without special cooling requirements.
Öne çıkanlar
- Online double-conversion with zero transfer time protects critical loads
- Energy Star 2.0 certified and up to 98% ECO-mode efficiency cuts energy cost
- 0 output power factor delivers full 1350 W from 1500 VA rating
- Six NEMA 5-15R outlets with individual control enable remote reboot of hung devices
- Compact 2U rack/tower form factor fits dense IT environments
Teknik özellikler
| Brand | Vertiv |
|---|---|
| Series | Liebert |
| Model | GXT5-1500LVRT2UXL |
| International Version | 120V |
| Input Voltage Range | 60-150V |
| Input Frequency | 40-70Hz; Auto Sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500VA |
| Watts | 1350W |
| Output Voltage | 110/115/120/125VAC; (user-configurable); +/-3% |
| Outlets | 6 |
| Outlet Type | 6 x NEMA 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Half Load: 18.8 min Full Load: 6.7 min |
| Approvals | UL 1778 4th Edition and CSA 22.2 No 107.3 |
| Temperature | Operating Temperature: 32°F - 104°F (0°-40°) Storage Temperature: -4°F - 140°F (-20°-60°) |
| Humidity | 0% to 95%, non-condensing |
| Dimensions | 3.4" x 16.9" x 18.5" |
| Weight | 46.2 lbs. |
| Kargo ağırlığı | 26.04 kg |
| Koli boyutu | 617 × 569 × 262 mm |
Bu ürünle ilgili sorular
How much power does the GXT5-1500LVRT2UXL draw in Active ECO mode compared with online double-conversion?
Active ECO mode reaches up to 98% efficiency, reducing waste heat and fan noise during continuous operation while still conditioning power.
Which network card slot is required if I want remote monitoring through the optional RDU101 card?
The UPS includes an intelligent slot that accepts the optional RDU101 card for SNMP and web-based management without additional adapters.
Will the six NEMA 5-15R outlets on this UPS power older servers that only accept 110 V input?
Yes, output voltage is user-configurable to 110, 115, 120 or 125 VAC with ±3% regulation, matching legacy 110 V equipment.
Bu reyondan diğerleri
Müşteriler bunları karşılaştırdı
Aynı raf, aynı sipariş tamamlama — sekiz koin ve 30 dakikalık kur kilidi.
ModMyMods MOD-0002 3/8" ID x 1/2" OD Clear PVC Tubing DIY Cooling
- Clear