NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.
Antminer
Mines Kaspa at 21 TH/s using the kHeavyHash algorithm with 3150 W power draw and 75 dB noise in a 15.8 kg air-cooled chassis
The Antminer KS5 Pro is an application-specific integrated circuit designed to mine the kHeavyHash algorithm used by the KASPA network. It delivers a rated hashrate of 21 TH/s while drawing 3150 W from the wall. The unit targets operators who run dedicated mining infrastructure and need a single-purpose device for that algorithm.
The miner uses forced-air cooling inside a chassis measuring 430 x 195.5 x 290 mm and weighing 15.8 kg. Under normal load the system emits 75 dB of noise, a level typical for high-density rack equipment. Power draw remains steady at the rated 3150 W, so the electrical supply and cooling capacity must match that continuous load.
Connectivity is provided by a single RJ45 port operating at 10/100 M, which carries both pool traffic and the web-based management interface. No additional controllers, software licences or wireless modules are included; configuration and monitoring are performed through the built-in dashboard once the unit receives an IP address.
Selle toote kohta ei ole veel tehnilisi andmeid avaldatud.
Connect the RJ45 Ethernet 10/100M cable to your router, power the 3150W unit via its PSU cables, then access the web UI to enter your Kaspa pool credentials; the step often skipped is setting a static IP or DHCP reservation so the miner does not lose its address after a reboot.
The air-cooling fans and dust filters require periodic cleaning; expect to replace fan assemblies when noise rises above the rated 75 dB or airflow drops enough to raise chip temperatures.
Thermal throttling triggered by the 75 dB cooling system is the first ceiling; if ambient temperature climbs or filters clog, the 21TH/s hashrate will scale back to protect the ASICs.
Veel samast osakonnast
Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.
See, millega maksate, ja see, milles vaatate hindu.
Saadetud teie rahakotist kassas
Ainult kuvamiseks — kataloogi hinnad on dollarites
Ükski vääring ei vasta sellele.
Valige keel, milles sait teiega räägib.
Esimest korda siin?
Teil on juba konto?
Automaatset lähtestamist ei ole: see pood ei saada ühtegi e-kirja, seega pole ka ühekordset linki, mida küsida. Jätke aadress kontole alles, seda käsitletakse käsitsi.
Päring registreeritud
Teie postkasti ei jõua midagi — see pood ei saada e-kirju üldse. Keegi tegeleb sellega käsitsi.
Tuli meelde?