NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.
Antminer
Mines Kaspa at 21 TH/s using the kHeavyHash algorithm with 3150 W power draw and 75 dB noise in a 15.8 kg air-cooled chassis
The Antminer KS5 Pro is an application-specific integrated circuit designed to mine the kHeavyHash algorithm used by the KASPA network. It delivers a rated hashrate of 21 TH/s while drawing 3150 W from the wall. The unit targets operators who run dedicated mining infrastructure and need a single-purpose device for that algorithm.
The miner uses forced-air cooling inside a chassis measuring 430 x 195.5 x 290 mm and weighing 15.8 kg. Under normal load the system emits 75 dB of noise, a level typical for high-density rack equipment. Power draw remains steady at the rated 3150 W, so the electrical supply and cooling capacity must match that continuous load.
Connectivity is provided by a single RJ45 port operating at 10/100 M, which carries both pool traffic and the web-based management interface. No additional controllers, software licences or wireless modules are included; configuration and monitoring are performed through the built-in dashboard once the unit receives an IP address.
Za ovaj artikl još nisu objavljene specifikacije.
Connect the RJ45 Ethernet 10/100M cable to your router, power the 3150W unit via its PSU cables, then access the web UI to enter your Kaspa pool credentials; the step often skipped is setting a static IP or DHCP reservation so the miner does not lose its address after a reboot.
The air-cooling fans and dust filters require periodic cleaning; expect to replace fan assemblies when noise rises above the rated 75 dB or airflow drops enough to raise chip temperatures.
Thermal throttling triggered by the 75 dB cooling system is the first ceiling; if ambient temperature climbs or filters clog, the 21TH/s hashrate will scale back to protect the ASICs.
Također u ovoj kategoriji
Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.
Ono što šaljete, i ono u čemu gledate cijene.
Poslano iz Vašeg novčanika na blagajni
Samo prikaz — katalog je izražen u dolarima
Nijedna valuta ne odgovara.
Odaberite jezik na kojem Vam se stranica obraća.
Novi ste ovdje?
Već imate račun?
Ne postoji automatsko resetiranje: ova trgovina ne šalje e-poštu, stoga ne postoji jednokratna poveznica koju biste mogli zatražiti. Ostavite adresu uz svoj račun, netko će je ručno obraditi.
Zahtjev zaprimljen
Ništa neće stići u Vaš pretinac e-pošte — ova trgovina uopće ne šalje e-poštu. Netko će to ručno preuzeti.
Sjetili ste se?