Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.

Hinnavaatlus Logi sisse

Tripp Lite

Tripp Lite SU1000XLCD 1000VA 900W 120V Double-Conversion UPS Tower

SKU CH-8KWF-89963 MPN SU1000XLCD

Double-conversion UPS delivers 900W continuous power with 6.7 minutes runtime at full load and 18.5 minutes at half load

  • International Version120V
  • Input ConnectionNEMA 5-15P
  • VA Rating1000 VA
  • Watts900 Watts
  • Output Voltage120V
  • Output Frequency50 / 60 Hz

VA 1000 VA / LCD Screen

  • Double-conversion topology isolates equipment from all power disturbances
  • 900 watts continuous output supports critical servers and networking gear
  • Six NEMA 5-15R outlets provide protected connections for multiple devices
  • User-replaceable VRLA batteries extend service life without technician visits
  • LCD screen and USB/RS-232 ports enable real-time monitoring and automated shutdowns

Double-Conversion UPS for Critical Loads

The Tripp Lite SU1000XLCD is a 1000VA 900W double-conversion UPS that delivers continuous 120V power through its inverter. It suits servers, network gear and workstations that cannot tolerate any transfer time during outages or voltage irregularities.

Upgrade from Line-Interactive Units

Moving from a line-interactive UPS is worthwhile when equipment requires zero-break power or when input voltage frequently drifts outside safe limits. The double-conversion topology isolates connected loads from all utility anomalies including frequency variation and harmonic distortion.

Tower Installation with User-Replaceable Batteries

The tower form factor sits on a shelf or floor and connects via a NEMA 5-15P plug to six NEMA 5-15R outlets. Batteries are user replaceable and recharge from 10% to 90% in under three hours. The communications slot accepts an optional SNMP card; without it, remote network management is not available.

Põhijooned

  • Double-conversion topology isolates equipment from all power disturbances
  • 900 watts continuous output supports critical servers and networking gear
  • Six NEMA 5-15R outlets provide protected connections for multiple devices
  • User-replaceable VRLA batteries extend service life without technician visits
  • LCD screen and USB/RS-232 ports enable real-time monitoring and automated shutdowns

Tehnilised andmed

BrandTRIPP LITE
SeriesSMARTONLINE
ModelSU1000XLCD
International Version120V
Input ConnectionNEMA 5-15P
VA Rating1000 VA
Watts900 Watts
Output Voltage120V
Output Frequency50 / 60 Hz
Outlets6
Outlet Type(6) NEMA 5-15R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 6.7 min. (900W)
Half Load: 18.5 min. (450W)
Battery Recharge TimeLess than 3 hours from 10% to 90% (typical, full load discharge)
Battery ReplaceableUser replaceable batteries
AlarmsAudible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Interface Port(1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB
Surge Energy Rating190 Joules
TemperatureOperating Temperature Range: 32° to 104°F (0° to 40°C)
Storage Temperature Range: With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
Humidity0-96% non-condensing
Dimensions9.93" x 6.30" x 15.24"
Weight32.63 lbs.
Package Contents1000VA 900W 120V Double-Conversion UPS
USB cable
DB9 cable
Quick Start Guide
Tarnekaal15.20 kg
Pakendi mõõtmed462 × 368 × 251 mm

Selle mudeli teised versioonid

3 veel samast sarjast

Sama seeria, erinev mälumaht, jahutus või taktsagedus — võrrelge enne otsustamist.

Küsimused selle toote kohta

What clearance does the tower UPS need for ventilation?

The operating temperature range is 32° to 104°F, so leave space around the tower for airflow within that range.

Which cable do I plug into the server for automatic shutdown?

Use the USB port with the included cable, then install the power-management software to enable unattended shutdown.

How often should the VRLA batteries be swapped?

Typical VRLA life is three to five years; the front-panel LCD will show a replace-battery warning when capacity drops.

Veel samast osakonnast

Kliendid võrdlesid neid ka

Sama osakond, sama kassa — kaheksa krüptovaluutat ja 30-minutiline kursilukk.