Tripp Lite SU1500XLCD 1500VA 1350W 120V Double-Conversion UPS Tower
- 120V
- NEMA 5-15P
Tripp Lite
Double-conversion UPS delivers 900W continuous power with 6.7 minutes runtime at full load and 18.5 minutes at half load
VA 1000 VA / LCD Screen
The Tripp Lite SU1000XLCD is a 1000VA 900W double-conversion UPS that delivers continuous 120V power through its inverter. It suits servers, network gear and workstations that cannot tolerate any transfer time during outages or voltage irregularities.
Moving from a line-interactive UPS is worthwhile when equipment requires zero-break power or when input voltage frequently drifts outside safe limits. The double-conversion topology isolates connected loads from all utility anomalies including frequency variation and harmonic distortion.
The tower form factor sits on a shelf or floor and connects via a NEMA 5-15P plug to six NEMA 5-15R outlets. Batteries are user replaceable and recharge from 10% to 90% in under three hours. The communications slot accepts an optional SNMP card; without it, remote network management is not available.
| Brand | TRIPP LITE |
|---|---|
| Series | SMARTONLINE |
| Model | SU1000XLCD |
| International Version | 120V |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000 VA |
| Watts | 900 Watts |
| Output Voltage | 120V |
| Output Frequency | 50 / 60 Hz |
| Outlets | 6 |
| Outlet Type | (6) NEMA 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load: 6.7 min. (900W) Half Load: 18.5 min. (450W) |
| Battery Recharge Time | Less than 3 hours from 10% to 90% (typical, full load discharge) |
| Battery Replaceable | User replaceable batteries |
| Alarms | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
| Interface Port | (1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB |
| Surge Energy Rating | 190 Joules |
| Temperature | Operating Temperature Range: 32° to 104°F (0° to 40°C) Storage Temperature Range: With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C) |
| Humidity | 0-96% non-condensing |
| Dimensions | 9.93" x 6.30" x 15.24" |
| Weight | 32.63 lbs. |
| Package Contents | 1000VA 900W 120V Double-Conversion UPS USB cable DB9 cable Quick Start Guide |
| 배송 무게 | 15.20 kg |
| 포장 크기 | 462 × 368 × 251 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
The operating temperature range is 32° to 104°F, so leave space around the tower for airflow within that range.
Use the USB port with the included cable, then install the power-management software to enable unattended shutdown.
Typical VRLA life is three to five years; the front-panel LCD will show a replace-battery warning when capacity drops.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?