Accettiamo criptovalute — così le crypto che Lei possiede possono comprare hardware reale.Paghi in crypto, la spenda in hardware reale. Spedizione assicurata gratuita in tutto il mondo oltre i 399 $. Cartoni neutri, senza marchio, spediti dalla Germania.Spedizione assicurata gratuita oltre i 399 $. Il Suo tasso resta bloccato per 30 minuti dall’apertura del checkout.Tasso bloccato 30 minuti. Ogni articolo è sigillato, il numero di serie è verificato, ed è coperto da una garanzia di 24 mesi.Sigillato, garantito 24 mesi.

Articoli preferiti Accedi

Tripp Lite

Tripp Lite SU1000XLCD 1000VA 900W 120V Double-Conversion UPS Tower

SKU CH-8KWF-89963 MPN SU1000XLCD

Double-conversion UPS delivers 900W continuous power with 6.7 minutes runtime at full load and 18.5 minutes at half load

  • International Version120V
  • Input ConnectionNEMA 5-15P
  • VA Rating1000 VA
  • Watts900 Watts
  • Output Voltage120V
  • Output Frequency50 / 60 Hz

VA 1000 VA / LCD Screen

  • Double-conversion topology isolates equipment from all power disturbances
  • 900 watts continuous output supports critical servers and networking gear
  • Six NEMA 5-15R outlets provide protected connections for multiple devices
  • User-replaceable VRLA batteries extend service life without technician visits
  • LCD screen and USB/RS-232 ports enable real-time monitoring and automated shutdowns

Double-Conversion UPS for Critical Loads

The Tripp Lite SU1000XLCD is a 1000VA 900W double-conversion UPS that delivers continuous 120V power through its inverter. It suits servers, network gear and workstations that cannot tolerate any transfer time during outages or voltage irregularities.

Upgrade from Line-Interactive Units

Moving from a line-interactive UPS is worthwhile when equipment requires zero-break power or when input voltage frequently drifts outside safe limits. The double-conversion topology isolates connected loads from all utility anomalies including frequency variation and harmonic distortion.

Tower Installation with User-Replaceable Batteries

The tower form factor sits on a shelf or floor and connects via a NEMA 5-15P plug to six NEMA 5-15R outlets. Batteries are user replaceable and recharge from 10% to 90% in under three hours. The communications slot accepts an optional SNMP card; without it, remote network management is not available.

Punti di forza

  • Double-conversion topology isolates equipment from all power disturbances
  • 900 watts continuous output supports critical servers and networking gear
  • Six NEMA 5-15R outlets provide protected connections for multiple devices
  • User-replaceable VRLA batteries extend service life without technician visits
  • LCD screen and USB/RS-232 ports enable real-time monitoring and automated shutdowns

Caratteristiche tecniche

BrandTRIPP LITE
SeriesSMARTONLINE
ModelSU1000XLCD
International Version120V
Input ConnectionNEMA 5-15P
VA Rating1000 VA
Watts900 Watts
Output Voltage120V
Output Frequency50 / 60 Hz
Outlets6
Outlet Type(6) NEMA 5-15R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 6.7 min. (900W)
Half Load: 18.5 min. (450W)
Battery Recharge TimeLess than 3 hours from 10% to 90% (typical, full load discharge)
Battery ReplaceableUser replaceable batteries
AlarmsAudible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Interface Port(1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB
Surge Energy Rating190 Joules
TemperatureOperating Temperature Range: 32° to 104°F (0° to 40°C)
Storage Temperature Range: With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
Humidity0-96% non-condensing
Dimensions9.93" x 6.30" x 15.24"
Weight32.63 lbs.
Package Contents1000VA 900W 120V Double-Conversion UPS
USB cable
DB9 cable
Quick Start Guide
Peso di spedizione15.20 kg
Dimensioni del pacco462 × 368 × 251 mm

Altre versioni di questo modello

altri 3 nella stessa gamma

Stessa famiglia, con memoria, dissipatore o frequenza diversi — confronti prima di decidere.

Domande su questo articolo

What clearance does the tower UPS need for ventilation?

The operating temperature range is 32° to 104°F, so leave space around the tower for airflow within that range.

Which cable do I plug into the server for automatic shutdown?

Use the USB port with the included cable, then install the power-management software to enable unattended shutdown.

How often should the VRLA batteries be swapped?

Typical VRLA life is three to five years; the front-panel LCD will show a replace-battery warning when capacity drops.